Alto-Shaam AR-6G User Manual

Page 11

Advertising
background image

AR-6G Rotisserie Operation & Care Manual • 9

I n s t a l l a t I o n

AR-6G Rotisserie Operation & Care Manual • 9

e l e c t r I c a l

An electrical wiring diagram is located under the

access panel beneath the drip tray of the appliance.

This appliance must be branch circuit protected with

proper ampacities, in accordance with the wiring

diagram located in the electrical compartment of the

appliance. The appliance must be properly grounded

in accordance with the National Electrical Code and

applicable local codes.

Wire size for the main incoming power to the unit must

match the minimum size listed in the specifications

applicable to the specific appliance.

D a n G e r

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

D a n G e r

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

D a n G e r

electrIcal GroUnDInG
InstrUctIons:

This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.

D a n G e r

aVertIssement:

Directives

pour la prise de courant électrique Cet
appareil est muni d'une fi che à trios
branches (prise de Courant) afi n de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fi che.

NEMA

5-15P

15A, 125V

PLUG

electrIcal

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

KW

120

1

60

5.83 0.7

Wire diagrams are located in the inside access panel of the unit .