AR-6G Rotisserie Operation & Care Manual • 12

I n s t a l l a t I o n

AR-6G Rotisserie Operation & Care Manual • 12

G a s c o n n e c t I o n s

The installation of this appliance must be completed by

a qualified installer familiar with the local codes and

regulations governing the installation of commercial gas

appliances. The installation must be made in accordance

with local codes or, in the absence of local codes, with

the National Fuel Gas Code ANSI Z223.1 (latest edition).

In Canada, the appropriate code is the Natural Gas

Installation Code, CAN/CGA-B149.1 or the Propane

Installation Code, CAN/CGA-B149.2.

q

Both the appliance and the individual appliance shutoff

valve must be disconnected from the gas supply piping

system during any pressure testing of that system at

test pressures in excess of 1/2 psi (3.45 kPa).

q

The appliance must be isolated from the gas supply

piping system by closing the individual appliance

manual shutoff valve during any pressure testing of the

gas supply piping system at test pressures equal to or

less than 1/2 psi (3.45 kPa).

Use an approved gas pipe sealant at all external threaded

connections. Gas piping used on gas connections must

avoid sharp bends that may restrict the flow of gas to the

appliance. If the connected pressure exceeds 14.0" W.C.

(3.5 kPa), a step-down regulator is required to be supplied

by the owner/operator.

Close the individual manual shut-off valve to isolate

the appliance from the gas supply piping system during

any pressure testing at test pressures equal to or less

than 1/2 psig. (3,4 kPa). The appliance and individual

shut-off valve must be disconnected from the gas supply

piping system during any pressure testing at pressures

in excess of 1/2" psig. (3,4 kPa).

In the U.S.A., installation must conform to local codes

or, in the absence of local codes, with the current

edition of the National Fuel Gas Code, NFPA-54 and

ANSI Z83.11a CSA 1.8a 2004 (or latest edition). In

Canada, installation must be in accordance with local

codes, CAN/CGA-B149.1, Installation for Natural Gas

Burning Appliances and Equipment (latest edition)

or CAN/CGAB149.2 Installation for Propane Burning

Appliances and Equipment (latest edition).

The inlet supply line must be properly sized to

accommodate all individual appliances simultaneously

used on the same line but must never be smaller than

3/4" NPT.

INCORRECT

CORRECT

A
B

C

D

E

F

G

H

Gas IntaKe

A-G Installation elbow

B Wall valve

C-D Three-piece union fitting

(minimum 1 per installation)

E-F End connector for the

flexible tube

h Marking line

D a n G e r

Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certifi ed service
technician qualifi ed to work on
gas appliances.

D a n G e r

DO NOT store or use gasoline or other
fl ammable vapors or liquids in the
vicinity of this or any other appliance.

D a n G e r

NE pAS entreposer ni utiliser
d'essence ou d'autres vapeurs ou
liquides infl ammables à proximité de
cet appareil ou de tout autre appareil.