AR-6G Rotisserie Operation & Care Manual • 10

I n s t a l l a t I o n

AR-6G Rotisserie Operation & Care Manual • 10

a I r s U p p l y

aIr sUpply

Installation of this appliance must include a

provision for an adequate flow of fresh air for gas

combustion. This requirement must be observed

by the installer as well as the operator. The rear of

the appliance provides air supply access for gas

combustion and must be kept clear at all times

.

Make certain the installation maintains adequate

air ventilation to provide cooling for electrical and

gas components. The area around the appliance

should be clear of any obstructions which might

retard the flow of cooling air. Failure to observe

this caution may result in damage to the control

components and will void the warranty.

Local and the National Fuel Gas Code provide

rules for determining the amount of fresh air

necessary for combustion and ventilation of

commercial cooking appliances. The codes will help

determine if additional outside air may be necessary

to meet health and safety regulations.

aIr aDJUstments

The appliance can be field converted from one type of

gas to another (natural gas to propane or vice versa).

After taking the necessary safeguards for the gas circuit

by employing the shut-off valve located at the rear of the

appliance, and disconnect the appliance from the electric

supply. Open the right-hand machine compartment.

Replace orifices as shown in chart.

Replace valves located under access panel.

Set manifold pressure as shown in chart.

If any gas fittings are loose or have been replaced, perform

the following test:

q

Use a soap and water solution to check all fittings for

leaks. Brush solution on all joints or areas where a leak

may be present. If bubbles appear, re-tighten the fitting

and recheck. If bubbles persist, replace the fitting.

Always reconnect the gas line and inspect for leaks before

replacing access panels.

NATuRAl

pROpANE

Top Orifice

OR-28127

# 29

OR-28132

# 43

Middle Orifice

OR-28128

# 20

OR-28191

# 41

Bottom Orifice

OR-28129

# 1

OR-28130

# 38

Manifold Pressure

5.0 µ/wc

10.0 µ/wc

c a U t I o n

DO NOT uSE CIRCulATING FANS
ON ThE FlOOR. FlOOR FANS WIll
AFFECT BuRNER OpERATION.

optIonal conVersIon KIts

Natural Gas to Propane

5008903

Propane to Natural Gas

5008904

c a U t I o n

CONvERSIONS MuST BE
pERFORMED By A CERTIFIED
SERvICE TEChNICIAN QuAlIFIED TO
WORk ON GAS ApplIANCES.

c a U t I o n

MAkE CERTAIN ThE AREA AROuND
ThE REAR OF ThE ApplIANCE IS
kEpT ClEAR OF OBSTRuCTIONS TO
AllOW A CONTINuOuS Supply OF
FRESh AIR FOR GAS COMBuSTION.