Troubleshooting _ 130 – Samsung SCX-8128NA-XAA User Manual

Page 130

Advertising
background image

Troubleshooting_ 130

4. Remove the new imaging unit from its package.

SCX-812x Series

CLX-92x1 / 93x1 Series

Do not use sharp objects, such as a knife or scissors, to open the

imaging unit package. You could damage the surface of the

imaging unit.

5. Go to step.9 (CLX-92x1 Series only).
6. Pull out the protecting pad (SCX-812x Series only).

If toner gets on your clothing, wipe it off with a dry cloth and wash

clothing in cold water. Hot water sets toner into fabric.

Be careful not to scratch the surface of the imaging unit.

To prevent damage, do not expose the imaging unit to light for

more than a few minutes. Cover it with a piece of paper to

protect it if necessary.

7. Pull the rubber stopper out of the developer (SCX-812x Series only).

8. Remove the tape on the imaging unit (SCX-812x Series only).

9. Remove the paper protecting the imaging unit.

SCX-812x Series

CLX-92x1 / 93x1 Series

10. Hold the handles on the new imaging unit, and push the imaging unit

until it locks into place.

CLX-92x1 / 93x1 Series

SCX-812x Series

2

1

Advertising