AMX NOVARA DCS1000 Device Configuration Software

52

Novara ControlPads & KeyPads

Viewing RS232 Libraries

To view the RS232 libraries, open the RS232 window then click the View RS232 Library button to open the
AMX RS232 Library dialog (FIG. 34).

This dialog displays the currently selected RS232 Library contents

To view a functions’ Protocol and string settings:

1.

Select the device from the Device Model and Description drop-down menu

2.

Select a function from the Function drop-down menu.

All the relevant information will be displayed.

The Device Protocol can be changed by selecting new settings for Baud rate, Data bits and Stop
bits
from their respective drop-down menus.

Command strings can be edited by changing Byte values via their individual drop-down menus
(0-255).

All Byte values are entered in Hex, Ascii or Decimal (selectable via the Code Format menu item).

When an edit is complete, click the Save Edit button to store the new values.

FIG. 34

AMX RS232 Library dialog

Device Protocol

Byte values

Menu Bar

Edit options window

Device Selection

Function Selection

PC Serial (Comm) Port Selection

(available only if PC Serial Port is selected

in the Connect To Device menu)

Connect to Device menu

(Serial or RS232)

Close this dialog