AMX Novara 1000 Series User Manual

Page 67

Advertising
background image

AMX NOVARA DCS1000 Device Configuration Software

61

Novara ControlPads & KeyPads

Creating New IR Libraries Using an IRIS IR/Serial Data Capture Device

To create new libraries using a manufacturers handset and an AMX IRIS Unit (FIG. 50):

1.

In the AMX IR Libraries dialog, select File > New.

2.

In the Save As dialog, enter a name for the Library File and click Save.

3.

In the AMX IR Libraries dialog, click Add New Device to invoke the Add New Device fields (FIG. 30):

4.

Enter the Device Make (model) and Description, and click Save Device.

5.

Click on Learn new function to invoke the Learn Function fields (FIG. 52):

6.

Connect the IRIS to your PC:

a.

Connect an RS-232 cable to the DB-9 connector on the IRIS unit and an RS-232 port on your PC.

b.

Set the baud rate in the IRIS unit to match the PC baud rate.

The IRIS (FG5448) is a stand-alone, self-contained unit used to capture IR or wired
function signals from a hand controller. Once captured and verified, the control
functions are sent to a PC operating the IRLIB program. For details on using the IRIS,
refer to the IRIS Operation/Reference Guide (available at www.amx.com).

FIG. 50

AMX IRIS IR Capture Unit

FIG. 51

AMX IR Library dialog - Add New Device fields

FIG. 52

AMX IR Library dialog - Learn New Functions fields

Advertising
This manual is related to the following products: