9

Cameras need to be installed according to the numerical order displayed
on the diagrams above. Whether you have one, two, three or four
video cards, the pattern is the same - cameras will be installed from
left to right starting with the top row for EYES Pro
and from top
to bottom beginning with the left-most column for
MP2016/MP3000/MP5000.

1.8 Connecting External Sensor/Relay

Each system can come with optional External I/O Boxes and D-type 15-
pin connector cables enabling you to connect sensor inputs and relay
outputs. The pin signals and specifications for the external I/O Box and
the D-type 15-pin connectors are described below.

D-type 15-pin Connector Cable

External I/O Box

Video Card

External I/O Box

Relay Outputs 3

Sensor Input 3

Relay Output 2

Sensor Input 2

Sensor Input 1

Relay Output 1

D-type 15-pin connector

Sensor Input 4

AVerMedia User’s Manual

EYES Pro/MP2016/MP3000/MP5000

10

Sensor Input Specification

Relay Output Specification
Surge strength: 1500 VAC
Nominal power 200mw ~ 360mw
Operating power 110mw ~ 200mw

COIL RATINGS (at 20

o

C)

Coil Nominal
Voltage

(VDC)

Coil
Resistance (

10% )

Pick-up
Voltage
(VDC)

Drop-Out
Voltage

(VDC)

Nominal
Current
(mA)

5

125

3.75

0.5

40

* Max Continuous Voltage at 20

o

C : 110% of Coil Nominal Voltage

Advertising