307

Held Period
Specifies the amount of time in seconds the supplicant is to
refrain from retrying to re-contact the authenticator in the event
the end user provides an invalid username and/or password.
Once the time period has expired, the supplicant can attempt to
log on again. The range is 0 to 65,535 seconds. The default value
is 60 seconds.

Max Start
Specifies the maximum number of times the supplicant will send
EAPOL-Start frames before assuming that there is no
authenticator present. The range is 1 to 10. The default is 3.

Start Period
Specifies the time period in seconds between successive attempts
by the supplicant to establish contact with an authenticator when
there is no reply. The range is 1 to 60. The default is 30.

User Name
Specifies the username for the switch port. The port sends the
name to the authentication server for verification when the port
logs on to the network. The username can be up to 30
alphanumeric characters (A to Z, a to z, 1 to 9). Spaces are allowed,
but special characters, such as an asterisk or exclamation point,
should be avoided. The username is case-sensitive.

User Password
Specifies the password for the switch port. The port sends the
password to the authentication server for verification when the
port logs on to the network. The password can be up to 16
alphanumeric characters (A to Z, a to z, 1 to 9). Spaces are allowed,
but special characters, such as an asterisk or exclamation point,
should be avoided. The password is case-sensitive.

4. Click Apply.

5. To permanently save the changes, select the Save Config menu

selection.