Setting the Switch’s Temperature Threshold

The switch sends an SNMP trap to your management workstation when
this adjustable temperature threshold is exceeded. The default
threshold is 60

°

Celsius.

To change the temperature threshold for the switch, do the following:

1. From the Main Menu, type 5 to select System Administration.

2. From the System Administration menu, type 2 to select System

Configuration.

3. From the System Configuration menu, type 9 to select Configure

System Hardware.

The Configure System Hardware menu is shown in Figure 15.

Figure 15 Configure System Hardware Menu

The menu displays the current temperature threshold for the
switch.

4. Type 1 to select Temperature Threshold and, when prompted, enter

a new threshold value. The range is 0

° to 60° Celsius.

5. After making the change, type R until you return to the Main Menu.

Then type S to select Save Configuration Changes.

Allied Telesyn Ethernet Switch AT-8524M - AT-S62

Production Switch

User: Manager

11:20:02 02-Jan-2004

Configure System Hardware

1 - Temperature Threshold (Celsius) .......... 60 C

R - Return to Previous Menu

Enter your selection?