75

‰ Verify that the twisted pair cable is Category 5 or 5E.

‰ Verify that the twisted pair cable is not faulty.

‰ Use the AT-S62 management software to determine whether PoE

is enabled on the switch and the port. The default setting for PoE
is enabled.

‰ Use the management software to determine whether the PoE

power setting for the port has been reduced from the default
setting of 15.4 W, to a value below the power requirements of the
device.

‰ PoE is not supported on expansion modules.

‰ Verify that the power budget on the switch is not being exceeded

by the powered devices. This should not be a problem for the
AT-8524POE switch, which can support powered devices on all
ports 1 to 24, even when all devices require the maximum of 15.4
W.

Check the FAULT LED. During normal operations, the LED remains off,
except for periods when the management software is saving a change to
its configuration. If it remains on for an extended period, do the
following:

‰ Try resetting the switch by disconnecting and reconnecting the

AC power cord. If the switch is a DC model, reset the unit by
powering off and the powering on the DC circuit.

‰ If the FAULT LED remains ON, try downloading a new version of

the switch’s management software through the RS-232 terminal
port on the front panel of the switch. For instructions, refer to the
switch’s software management guide.

‰ If the LED remains on even after you have tried the above

suggestions, the switch may be having a hardware problem.
Contact your Allied Telesyn representative for assistance.

If you are unable to establish a local management session with the
switch through the RS-232 terminal port on the front panel, do the
following:

‰ Check to be sure that the RS-232 cable is securely connected to

the RS-232 terminal port on the switch and to the RS-232 port on
the terminal or personal computer.

‰ Check to be sure that you are using a straight-through RS-232

cable. Do not use a cross-over cable.