There are two levels of management access on an AT-8400 switch:
Manager and Operator. When you log in as a Manager, you can view and
configure all of a switch’s operating parameters. When you log in as an
Operator, you can only view the operating parameters. As an Operator,
you cannot change any values.

Log in as a Manager or an Operator by entering the appropriate login id
and password when you start an AT-S60 management session. The
default password for Manager access is “friend.” The default password
for Operator access is “operator.” The passwords are case-sensitive.

To change the Manager or Operator password, perform the following
procedure:

1. From the Main Menu, type 4 to select Administrator Menu.

2. From the Administrator Menu, type 7 to select Set Password.

The Passwords Menu is shown in Figure 12.

Figure 12 Passwords Menu

3. To change the Manager password, type 1. To change the Operator

password, type 2. Follow the prompts. The password can be from 0 to
20 alphanumeric characters. The passwords are case-sensitive.

Caution

Allied Telesyn recommends that you do not use spaces or special
characters, such as asterisks (*) and exclamation points (!), in a
password if you are managing the switch from a web browser. Many
web browsers do not accept special characters in passwords.

Note

You must assign different values to each password.

Allied Telesyn AT-8400 Series - ATS60 V2.0.0

High School Switch 142

User: Manager

00:14:33 15-Jan-2003

Passwords Menu

1 - Set Manager Password
2 - Set Operator Password

R - Return to Previous Menu

Enter your selection?