GROUNDING and BONDING CONSIDERATIONS

• Grounding is very important in tower top applications. Shipped with each MHU, is a 4mm

(#6 AWG), one-meter (39-inch) ground cable with single hole crimp lug connectors on
both ends. Installation hardware is provided to attach one end to the MHU.

• Keep ground wire as short and direct (no loops or knots) as possible, secure it to a good

ground point (metal to metal).

• Always follow local grounding practices. The single hole lug is typically used to attach a

dedicated tower ground bus.

• In the absence of a dedicated ground, the tower structure itself can be used by using a

exothermic weld joint (not very common) or a mechanical ground clamp. If a clamp is
used, it must be very tight and protected from corrosion effects with a corrosion
preventative compound. It is recommended that the ground integrity/resistance at any
mechanical junction be checked during periods of regular tower maintenance. Always
follow local grounding practices.

• If the ground cable length is too short, customer may make a longer ground cable using

4mm (#6 AWG) wire as long as all the mechanical connections are tight and clean. Keep
ground cables as short as possible.

2.2.2

Installing Coaxial Cables

Four short coaxial jumpers should be pre-made. Two will connect the BTS ports to the hard line
and the other two will connect the ANT ports to the antenna.

Most installations require four good quality flexible coax jumpers, normally terminated with 7/16
DIN-7/16 DIN connectors. Check gender of hard line and determine if antenna pigtail is present,
adjust accordingly for a correct match.

The coaxial feeder that runs from the base station to the antenna should be attached to the BTS
port of the MHU using a jumper cable. The reason for the jumper cable is to ensure that
mechanical forces caused by temperature change will not damage the MHU connectors. Tighten
connectors to 25–30 Nm (18.43–22.13 ft. lbs.) torque.

To improve connection reliability the connector joint can be protected. This is done, by
installing specific weatherproof tape over the cable connectors. Loose cable should be secured
to the tower using cable brackets.

Caution: Before connecting any coaxial cables, ensure that the BTS transmitter output is
turned off and that precautions are taken to ensure that the transmitter cannot be activated
during the equipment installation.

Caution: Remote Electrical Tilt (RET) connector on MHU must be covered with protective cap
if a cable is not connected to meet IP65 rating.