2 troubleshooting hints, Troubleshooting hints – ADC ClearGain Dual Inline Tower Mounted Amplifier System User Manual

Page 20

Advertising
background image

ADCP-75-214 • Issue 2 • September 2006

Page 14
© 2006, ADC Telecommunications, Inc.

4. Re-connect Bias-T with a T adapter. Verify voltage on the T adapter _______ VDC.

Normal is 15 VDC.

5. Re-connect to original configuration and return to service. PDU should illuminate a green

LED for each active TMA if there are no faults in the system.

6. Check with operators for improved performance.

4.2

Troubleshooting Hints

• If voltage is outside of the normal range, trace it back towards the fault.

• If no resistance or low resistance, check protector, feedline, jumpers and MHU.

• If an infinite resistance reading (sometimes indicated by OL), check to see if MHU is

installed or for a discontinuity exists up to the MHU.

• Normal in-band RL should be greater than 18dB. If less than 18dB, check protector,

feedline, jumpers and antenna.

• Mark receive and transmit bands to verify correct filtering.

• Check the distance to fault to identify any anomalies on the feedline.

PDU

Advertising