ADCP-75-214 • Issue 2 • September 2006

Page 15

© 2006, ADC Telecommunications, Inc.

4.3

Troubleshooting Flowchart (For Systems With Three-Port MHUs)

If directed by the flowchart, refer to the troubleshooting matrix in

Section 4.4

or to the return

loss sweep guide in

Section 4.5

.

ANY

LIGHTS ON

THE PDU?

ALARM

led

MHU

led

START

NO

OFF

YES

OFF

OFF

RED

MHU

led

YELLOW

SOLID

GREEN

The red Alarm led should come on
when any MHU select dip switch
is pushed to the down position. If
the bias-t connection is not made.

• CHECK DC CONNECTIVITY
TO

THE

• CHECK MHU PORT FOR 18VDC.
IF NOT PRESENT, REPLACE PDU.

• CHECK BIAS-T CABLE FOR

18VDC. IF NOT

PRESENT,

REPLACE BIAS-T CABLE.

• CHECK BIAS-T FOR 18VDC.
IF

NOT

PRESENT, REPLACE BIAS-T.
• CHECK RESISTANCE OF
FEEDLINE.

-

LO OHMS OR

SHORTED;
PROBLEM

TOP

SIDE.

-

HI OHMS OR OPEN IS

NORMAL

BUT ALSO MAY INDICATE A

DISCONTINUITY.

• CHECK SUPPLY IS -56 to -20 VDC or +20 to +56 VDC.

The red lead is connected to the higher potential.

• CHECK SUPPLY FUSE/BREAKER IS OK. (5A RATING)

• CHECK DC CABLE AND CONNECTION.PROBLEM

The red Fail led should come on when any MHU
select dip switch is pushed to the down position. If
the bias-t connection is not made.

TTA ACTIVE

ONE

PATH

FAILING

PDU OR

CONNECTIVITY

PROBLEM

REFER TO TROUBLESHOOTING MATRIX

21401-A