background image

ADCP-75-214 • Issue 2 • September 2006

Page 16
© 2006, ADC Telecommunications, Inc.

4.4

Troubleshooting Matrix

If directed in

Section 4.3

to consult a troubleshooting matrix, see

Table 1

below.

Note: ClearGain PDU DIP switches must be in the down position for each active MHU!

Note: ClearGain PDU input voltage must be in the range –56 to –20 VDC or +20 to +56 VDC.

Table 1. Troubleshooting Matrix

PARAMETER

SPECIFICATION

EXPLANATION

GREEN/YELLOW
OK LED

RED GENERAL
ALARM LED

Electronic Load

Each Path OFF

< 180 mA

Fail

OFF

ON

Each Path ON

180 – 220 mA

OK

GREEN

OFF

Total Fail

370 – 400 mA

Fail

OFF

ON

Short Circuit
Protection

1.5 A ± 10%

Fail

GREEN

ON

Short state of MHU path does not affect other path. After generating Green alarm,
the short state is held for ten seconds then Red alarm is generated by the PDU.

Circuit Fluctuation Min 180 mA

Max 380 mA

One path failed.

YELLOW

ON

Input Voltage

–56 to –20 VDC /
+20 to +56 VDC

OK

GREEN

OFF

Output Voltage

15 V, 4%

Total failure.

OFF

ON