6.0 DELIMING PROCEDURE

CAUTION: Read and follow instructions on the CLR bottle. Use plastic
or rubber gloves to avoid skin contact. If CLR comes in contact with
skin, rinse with clean water.


1. Completely drain steam generator by setting on/off switch to “OFF”. Set cooking timer to

0.


2. Set on/off switch to DELIME.

3. Unscrew deliming port located in front of generator. Screw in the supplied deliming

funnel. Make sure funnel is in upright position. Pour 200 ounces of solution into
generator slowly to avoid spillage. Remove funnel and screw in delime port cap
securely. Turn on/off switch to “ON”.


4. Operate steamer in READY cycle for ½ hour, then turn on/off switch “OFF” and allow

generator to drain.


5. Flush cycle. Turn on/off switch to “ON”. When ready light comes on, switch to “OFF” to

flush generator. Repeat this step three times to completely flush generator.


6. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean

water. Dry with a soft cloth. LEAVE COMPARTMENT DOOR OPEN WHEN NOT IN
USE.



The steamer is now ready for use. Turn off for overnight shutdown.

TWICE A YEAR:

At least twice a year, have an authorized service person clean and adjust the unit for
maximum performance.

All units are adjusted at the factory. In case of operation problems at initial installation,
check type of gas supply and manifold pressure and compare it with information on the
rating plate.

WARNING: Adjustments and service work may be performed only by a
qualified technician who is experienced in, and knowledgeable with the
operation of commercial gas cooking equipment. However, to assure
your confidence, contact your authorized service agency for reliable
service, dependable advice or other assistance and for genuine factory
parts.