7.0 TROUBLESHOOTING


Burners do not come on:

1. Gas supply to unit is “OFF”.

2. Power Switch is not turned “ON”.

3. Steam generator probe not sensing the water level, will not call for ignition.

4. Ignitor not functioning.

5. Gas combination supply valve not “Opening”.


Burners produce carbon deposits:


1. Wrong orifice size.

2. Wrong gas supply.

3. Incorrect pressure at supply.


Water flows into cooking compartment:

1. Short circuit between operating level probe and body inside steam generator.

2. Excessive scale build-up on operating probe.

3. Water fill solenoid valve is open, plugged or defective

These problems are an indication of severe harmful water conditions which should be
corrected immediately to avoid damage to the components and performance of the steamer.
Call your service agency for assistance.


Door leaks:

1. Check for damage to door gasket.