H2tu-c-231 list 2 adc config menu options – ADC H2TU-C-231 User Manual

Page 26

Advertising
background image

Provisioning

LTPH-UM-1109-01, Issue 1

18

January 9, 2002

H2TU-C-231 List 2

H2TU-R Line
Buildout

RLBO

Sets the DS1 receive level output toward the Customer Interface (CI). H2TU-R
Line Buildout can only be set through the maintenance screens.

0 dB

Sets the DS1 RLBO level toward the CI to 0 dB.

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

-15.0 dB

Sets the DS1 RLBO level toward the CI to -15.0 dB.

Alarm Pattern

See

“Alarm

Pattern (ALMP)
Option” on
page 20

.

ALMP

AIS

Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and DS1 LOS. See

Figure 26 on page 42

for LOS/AIS response

priorities.

LOS

Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and DS1 LOS.

H2TU-R TLOS
Loopback

TLOS

ENA

Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input.
See

Figure 26 on page 42

for LOS/AIS response priorities.

DIS

Disables Transmit Loss of Signal (TLOS) logic loopback.

Network
Loopback Pattern

NLBP

AIS

Enables the H2TU-R to transmit an AIS towards CI for any network loopback.
See

Figure 26 on page 42

for LOS/AIS response priorities.

LOS

Enables the H2TU-R to transmit an LOS towards CI for any network loopback.

Power Back Off -
Customer

See

“Power Back

Off (PBON and
PBOC) Options”
on page 20

.

PBOC

DEF

Configures the power output levels of the H2TU-R customer unit toward the
network to comply with the Default template as defined in Section 6.1.4.2 of
ANSI T1/E1.4.

ENH

Configures the power output levels of the H2TU-R customer unit toward the
network to comply with the Enhanced template as defined in Section 6.1.4.2
of ANSI T1/E1.4.

Power Back Off -
Network

See

“Power Back

Off (PBON and
PBOC) Options”
on page 20

.

PBON

DEF

Configures the power output levels of the H2TU-C-231 network unit toward
the customer to comply with the Default template as defined in Section
6.1.4.2 of ANSI T1/E1.4.

ENH

Configures the power output levels of the H2TU-C-231 network unit toward
the customer to comply with the Enhanced template as defined in Section
6.1.4.2 of ANSI T1/E1.4.

Table 6.

H2TU-C-231 List 2 ADC Config Menu Options

ADC Config Menu
Options

Front Panel
Display
Code

Selection

Description

Line Power Feed

PWRF

OFF

Disables powering to the HDSL2 pair.

ON

Keeps the HDSL2 line voltage at nominal -180 Vdc.

Remote
Provisioning

RTPV

ENA

Enables remote provisioning.

DIS

Disables remote provisioning.

Bipolar Violation
Transparency

See

“Bipolar

Violation
Transparency
(BPVT) Option”
on page 20

.

BPVT

ENA

Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted into
DS1 BPVs at the DS1 output at the distant end. This makes HiGain HDSL2
transparent to BPVs.

DIS

Disables BPV Transparency.

Continued

Table 5.

H2TU-C-231 List 2 Standard Config Menu Options (Continued)

Standard Config
Menu Options

Front-Panel
Display
Code

Selection

Description