LTPH-UM-1109-01, Issue 1

Monitoring System Activity and Performance

H2TU-C-231 List 2

January 9, 2002

25

3

To initiate a loopdown of all active loopbacks, press the

to select LPDN, then press

or

.

When prompted with the message:

Are you sure (Y/N)?

, press

to initiate the loopdown or

to

cancel.

Table 8.

Monitor Screen Descriptions

Field

Description

Active loopback

An active loopback is indicated on the lower third of the Monitor screen. Available loopbacks are
indicated by gray text. See

Table 16 on page 44

for a summary of the HiGain HDSL2 loopback

codes.

Alarm type

Indicates type of alarm.

Armed mode

Indicates system is in an armed state for an intelligent repeater (IR) loopback command.

BERT Status

Provides BERT Generator status, elapsed time, and BERT results.

Code type

Type of DS1 line coding received or sent (B8ZS or AMI).

DS1 ES Count

Errored Seconds—The sum of the Errored Seconds-Line (ES-L) and Errored Seconds-Path (ES-P)
counts detected on the DS1 input over a 24-hour period. Errors included are: DS1 Frame errors,
BPV, and ESF CRC errors.

DS1 SES Count

Severely Errored Seconds—The sum of the DS1 Severely Errored Seconds-Line (SES-L) and
Severely Errored Seconds-Path (SES-P) counts over the last 24 hours.

DS1 UAS Count

Unavailable Errored Seconds—The number of seconds during which the DS1 input signal was
absent over a 24-hour period.

Frame type

Type of DS1 framing detected at the input stream (SF, ESF, or UNFR).

HDSL2 ES Count

Errored Seconds—The number of 1-second intervals that contained at least one CRC or LOSW
error. This value is a running total of the last 24 Hours.

HDSL2 SES Count

Severely Errored Seconds—The number of 1-second intervals that contain at least 50 CRC errors
or one or more LOSW defects. (An LOSW defect occurs when at least three consecutive HDSL
frames contain one or more frame bit errors.) This value is a running total of the last 24 hours.

HDSL2 UAS Count

Unavailable Errored Seconds—The number of seconds the HDSL2 loop is unavailable. This occurs
after 10 contiguous HDSL SES seconds and is retired after 10 contiguous non-SES seconds. This
value is a running total of the last 24 hours.

ID

Circuit identification (ID) number.

LA

Loop Attenuation—Indicates the attenuation of the Overlapped Pulse Amplitude Modulation
Transmission with Interlocking Spectra (OPTIS) pulse from the distant end. The value is related to
the loop attenuation at 196 kHz and should be kept under 35 dB.

LPF

Line Power Feed—Indicates the HDSL2 line power is on.

M

Margin—The signal-to-noise (SNR) ratio at all HDSL2 ports, relative to a 10

-7

Bit Error Rate.

MAL

Margin Alarm—Indicates the margin on HDSL2 loop has dropped below the threshold (0 to 15 dB)
as set by the operator.

PL (or HG)

PL displays when the loopback was initiated by a command embedded in the DS1 data path
payload (PL). HG displays when the loopback was initiated from a HiGain (HG) front panel or by a
maintenance terminal loopback command.

PRM

The sum of the Performance Report Messaging-Near End (PRM-NE) and Performance Report
Messaging-Far End (PRM-FE) counts.

System Status

The presence or absence of an alarm condition is indicated on the lower right corner of all screens.
System: OK indicates that there are no alarms present; System: Alarm indicates the presence of
an alarm. Refer to

“Using the Performance Screens to View Alarm Data” on page 32

for detailed

alarm information.

SPACEBAR

ENTER

N

Y