Testing with h2tu-c bert generator, H2tu-c bert generator screen, Bert signal generator option settings – ADC H2TU-C-231 User Manual

Page 60: H2tu-c bert g, Esting with, Enerator

Advertising
background image

Testing

LTPH-UM-1109-01, Issue 1

52

January 9, 2002

H2TU-C-231 List 2

T

ESTING WITH

H2TU-C BERT G

ENERATOR

The H2TU-C BERT Generator screen allows transmission of a selected test signal from the H2TU-C towards
either the network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.

1

Press

to select the Config menu.

2

Use the

and

arrow keys to select BERT Generator, then press

.

3

Use the arrow keys to select an option and press the

to cycle through the settings. Refer to

Table 19

for a list of BERT generator option settings.

4

Press

to activate your choice.

5

To view BERT status, press

twice, then use the

arrow key to select the Monitor menu.

6

Press

. You can exit the status screen while signal generation is active.

Figure 29.

H2TU-C BERT Generator Screen

It is not recommended using the Bit Error Rate Tester from the remote and line unit at the same
time.

Table 19.

BERT Signal Generator Option Settings

Option

Description

BERT Signal Generator

Enabled (ENA) or Disabled (DIS)

BERT Signal Pattern

1:7 pattern, 2:8 pattern, 3:24 pattern, 2

23-1

pseudo random, 2

20-1

pseudo random, 2

15-1

pseudo random

BERT Signal Linecode

AMI or B8ZS

BERT Signal Direction

Toward CPE or toward NET

BERT Interval

5 minutes, 60 minutes, Continuous (default)

C

ENTER

SPACEBAR

ENTER

ESC

ENTER

Monitor

Performance

Event Log

Config

Inventory

Report

Rlogon

Help

+----------------------+
| Standard Options ->

|

| ADC Options

->

|

|

BERT Generator

->

|

+--------------------------------------+
| BERT Signal Generator

:

ENA

|

| BERT Signal Pattern

: 1 in 7

|

| BERT Signal Linecode

: AMI

|

| BERT Signal Direction

: NET only

|

| BERT Interval

: Continuous

|

+--------------------------------------+

Use <Spacebar> to cycle through option settings and <Enter> to activate