12

ENGLISH

Shavings or chips must not be removed when the equipment is running.

Dust that arises during work is often harmful to health and should not be allowed to enter the
body. Please wear a suitable dust protection mask.

Please remove the plug from the electric socket before all work on the equipment.

Be sure the equipment is switched off before connecting it to the electric socket.

Always keep the connecting cable away from the sphere of action of the equipment. Always
guide the cable away from the equipment to the rear.

Please look out for electric cables, gas and water pipes when working on the wall, ceiling or
floor.

2

Technical Data

RODIADRILL 2400 PD-E

RODIADRILL 3000 PD

Nominal acceptance power ......... 3000 W

4000 W

Gear ........................................... 1. ............... 2. ........... 3.

1. .............. 2. ........... 3.

Speed (min-1) ............................. 300 ............ 600 ........ 1120

215 ........... 430 ........ 785

Drilling range (

Ø mm) .................. 142-272 ..... 72-142 ... 30-72

180-520 .... 90-180 ... 30-90

Weight ........................................ approx. 9,0 kg

approx. 12,1 kg

Speed electronic ......................... yes

yes

Tool fitting ......................................................

outer 1.1/4“ UNC, inner G 1/2“

Vibration ..................................... 2,9 m/s2

2,9 m/s2

Drill bit types ............................... SPEED STAR DX, Duramant PRO, EUROLASER, DX-HSP

Personal protection coupling ....... yes, electronic and mechanic speed regulation

Typical A-rated sound level:

Noise pressure level (L

pA

) ........... 91 dB (A) ¦ K

pA

3 dB (A)

91 dB (A) ¦ K

pA

3 dB (A)

Sound power level (L

WA

) ............. 102 dB (A) ¦ K

WA

3 dB (A)

102 dB (A) ¦ K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 60745-1:2010.

3

Electric supply

Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate. Connection is also possible to sockets without earthing contact as this is a
protection class II assembly.

3.1

Putting the PRCD switch into operation

Only suitable for AC current! Note the mains network voltage!

Perform the following test procedure on the PRCD switch before every putting into operation of
the device:

1. Connect the PRCD plug connector with the socket.

2. Press on RESET. The indicator switches to ORANGE (ON).

3. Pull the plug connector out of the socket. The display switches itself off.

4. Repeat 1. and 2.

5. Press on TEST. The orange indicator switches itself off.

6. Press on RESET to switch the device on (ORANGE).

These protective device protect against faults in the attached device, not against such
faults in the preceding plant.