ROTHENBERGER RODIADRILL 3000 PD User Manual

Page 18

Advertising
background image

14

ENGLISH

4.3

Handling

Please read and be sure to understand the drill rig instruction manual.

Overload protection

The green control lamp illuminates during normal operation. The red control lamp illuminates if
excessive pressure is applied to the drill bit. Reduce the contact pressure; the green control
lamp illuminates again.

The electronic system shuts the equipment down in the case of overloading for a longer period
of time. Switch the equipment off and then on again in order to continue working. In the event of
jerky overloading (e.g. jamming of the drill bit) the electronically automatic switch off interrupts
the force flow.

Setting the speed
 Set the speed according to the diameter and the type of the material, according to the

label.

Only change gears when the equipment is at a standstill.

Wet drilling

Danger due to electric shock! Always carry out work using a water extraction
device when wet drilling overhead. The water extraction device must be in a
flawless condition.

 Turn on the water connection and switch on the water extractor.

(There must at least be sufficient water pressure (max. 4 bar!) to move the arising drilling
mud from the borehole)

 Switch on the motor.
 Apply the diamond drill bit and continue to drill using light, consistent follow-up pressure.
 Occasionally with draw the drill bit slightly from the bore so that the drilling mud or dust is

removed.

 Shut down the motor once the desired drilling depth has been achieved and pull the drilling

bit out of the borehole slowly.

 Stop the supply of water and shut down the water extractor.
 If no more boreholes are required, allow the motor to run again for a few seconds without

water supply in order to press the remaining water out of the rinsing bush of the motor.

In case of seizure, start up the drill motor again at low speed using cooling water
and withdraw the core bit.

In case of need, repeat the process or turn the core bit using the SW 41 flat wrench.

Please note: Switch off the PRCD switch!

Optional: Dry drilling

Reinforced concrete only wet drilling!

 Switch on the motor and the vacuum cleaner.
 Apply the diamond drill bit and continue to drill using light, consistent follow-up pressure.
 Occasionally with draw the drill bit slightly from the bore so that the drilling dust is removed.
 Shut down the motor once the desired drilling depth has been achieved and pull the drilling

bit out of the borehole slowly

 Shut down the vacuum cleaner.

Advertising
This manual is related to the following products: