38

(ROWELD P 250/8 B: the total cylinder surface is 6.26 cm²)
(ROWELD P 355/12 B: the total cylinder surface is 6.26 cm²)
(ROWELD P 500/18 B and P 630/24 B: the total cylinder surface is 14.13 cm²)
(ROWELD P 630/24 B Plus the total cylinder surface is 22.38 cm²)

3.5

Setting parameters

To set the parameters with „welder“ rights:

Press the adjusting knob (4) for a long time (about 3 sec.) until P001 blinks in the upper
display (2).

Use the adjusting knob (4) to select the desired parameter P001 to P009. If this value must
be adjusted or displayed, briefly press the adjusting knob (4). The (default) value blinks in the
lower display (9).

Use the adjusting knob (4) to set the value, and press the adjusting knob (4) briefly again.
Then the parameter blinks again in the upper display (2).

To leave the menu, press the release button (10). The values are stored.

How to set parameters with „master“ rights:

Press the adjusting knob (4) for an extended time (about 6 sec.). First the parameter P001
blinks in the upper display (2). Then „CodE“, and the line blinks in the first place in the lower
display (9).

Then use the adjusting knob (4) to enter the code, and briefly press the adjusting knob (4)
(code = 8001 – during first use the code can be changed as desired through parameter P100).

Use the adjusting knob (4) to select the desired parameter, P101 to P114. If this value must
be adjusted or displayed, briefly press the adjusting knob (4). The (default) value blinks in the
lower display (9).

Use the adjusting knob (4) to set the value, and press the adjusting knob (4) briefly again.
Then the parameter blinks again in the upper display (2).

To leave the menu, press the release button (10). The values are stored.

Parameter
name

Description

default Unit

min

max

Rights

P001

Remaining energy saver time

99

min

0

99

Welder

P002*

Power saving function active

0

0

3

Welder

P003

Heating plate temperature offset 5

°C

-25

25

Welder

P004

Pmax for cutting

20

bar

10

50

Welder

P005

Target pressure

1/10 bar

Welder

P006

Target temperature

210

°C

P103 P104

Welder

P007

Timer T1 target value

45

sec

1

1500 Welder

P008

Timer T4 target value

6

min

1

99

Welder

P009

Pstart for cutting

10

bar

0

P004

Welder

P101

Deviation for repumping

5

%

1

50

Master

P102

Lifting time after cutting

10

1/10 sec 0

100

Master

P103

Set temperature (min)

160

°C

0

300

Master

P104

Set temperature (max)

270

°C

0

300

Master

P105

Button lock (yes/no)

5

sed

0

50

Master

P106

Lifting pressure

135

bar

10

160

Master

P107

Full runtime until buzzer goes on 50

1/10 sec 0

200

Master

P100

Change code

8001

Master

* P002 - Power saving function:

0 - none,
1 - when the miller is running the heating element will be switched off,
2 - when the hydraulic motor is running the heating element will be switched off,
3 - when t4 is running the heating element will be switched off.