BASIC TROuBLESHOOTING
CONNECTED mODELS ONLy

Failure Events and Safety Control
Appliance Does Not Turn On.

Check to ensure the steamer is plugged into

̆

the correct receptacle.

Check the branch circuit breaker to insure it

̆

is in the “ON” position.

The mechanical over flow level control has

̆

been removed. The steamer will not start

up until the mechanical level control is

reinstalled.

Call AccuTemp Products Technical Service

̆

Toll Free at 800 480-0415 or at 260 469-

3040.

No/Low Water Pressure or No/Low Flow of

Water into the Reservoir.

Check the supply water pressure

̆

Check for dirty inlet screen.

̆

Check for dirty probes.

̆

Call AccuTemp Products Technical Service

̆

Toll Free at 800.480.0415 or 260.469.3040.

Appliance Shuts Down During Operation.

Check conditions listed above for no/low

̆

water pressure or no/low flow of water into

the reservoir.

If the water level control valve is stuck “on”,

̆

the mechanical overflow level control will

shut down the whole Steamer and the water

supply by turning off the master water control

valve.

If the water level sensing control board

̆

becomes faulty, the mechanical over flow

level control will shut down the Steamer.

Call AccuTemp Products Technical Service

̆

Toll Free at 800 480-0415 or at 260 469-

3040.

Never leave a deliming agent in contact with

1.

the stainless steel longer than 10 minutes

before rinsing the cooking compartment

thoroughly with water. Longer contact can

cause corrosion.
Do not use abrasive materials, such as wire

2.

brushes, metal scouring pads or scrapers to

clean the cooking compartment bottom.
Service must be performed only by

3.

AccuTemp Products, Inc. Preferred service

agents. Service performed by non-preferred

service agents will void all warranties.
Any in-field modification made without

4.

written authorization from AccuTemp will

void the warranty.

WARNING

Advertising