BuILDING CODES AND STANDARDS
The appliance must be installed in accordance

with the following building codes:

USA: National Electric Code, ANSI/NFPA-70,

state and local codes. International Plumbing

Code 2003, ICC or Uniform Plumbing Code

2003, IAMPO. Canada: Canadian Electric Code,

CSA C22.2 and state and local codes.
uNPACKING
This appliance was inspected before shipment

from the factory. The shipping company accepts

full responsibility for safe delivery. Immediately

after unpacking, check the appliance for possible

shipping damage. If damage is identified, save

the packaging material and contact the shipping

carrier within 15 days.
LOCATION AND PLACEmENT
To insure maximum benefit of your warranty;

location, placement and leveling are critical.

The AccuTemp STEAM’N’HOLD™ is designed

for installation on either a commercial kitchen

counter top or an AccuTemp STEAM’N’HOLD™

stand. Your appliance is equipped with vents to

allow the proper ventilation of air through the

electrical compartment. The vents are located on

the bottom and rear panel. To ensure these vents

work properly a minimum 3” (77 mm) clearance

from these vents must be allocated. It is also

recommended that the appliance not be placed

under other wet equipment or locations.
LEVELING
This appliance must be installed in a level

condition. An out-of-level condition may cause

improper operation and possible damage. Damage

caused by improper leveling is not covered by

warranty. Use a spirit level, resting on the top of

the appliance cabinet surface, to ensure it is level

front-to-back and left-to-right. If this is a counter-

top installation, be sure to install the rubber foot

tips provided with your appliance onto each foot

SINGLE STAND INSTALLATION
The AccuTemp SNH10 single stand is equipped

with adjustable height feet and the AccuTemp

SNH11 single stand is equipped with non-

adjustable height casters. Both can be used with

either a single S3 or S6 model STEAM’N’HOLD™.

Before mounting the appliance on the SNH11

stand, engage the brakes on the two front locking

casters, pressing on the “ON” handle of the brake

mechanism. To mount the appliance, carefully

lift and place it on the horizontal mounting

brackets, ensuring that the (4) mounting holes on

the underside of the appliance is lined up with

the mounting holes on the brackets. Then, using

a 7/16” wrench, fasten one pair of the ¼”-20

hex bolts and ¼” split lock washers through the

underside of each stand bracket mounting hole

into the appliance and tighten securely. With the

SNH10 stand, level the appliance by adjusting the

feet found at the ends of each stand leg, either up

or down as needed.

INSTALLATION

adjuster of each of the legs. This will keep the

appliance from sliding on the counter-top under

normal use. Once the rubber foot tips have been

installed, rotate the foot adjusters up or down as

needed to level the appliance

DOuBLE STAND INSTALLATION
The AccuTemp SNH20 double stand is

equipped with adjustable height feet and the

AccuTemp SNH21 double stand is equipped

with non-adjustable height casters. Both stands

can accommodate either two S6 models or two

S3 models or a single S3 model on the top and

a single S6 model on the bottom.
Before mounting a appliance on the SNH21

stand, engage the brakes on the two front

locking casters, pressing on the “ON” handle of

the brake mechanism. To mount the appliance,

carefully lift and place it on the bottom

horizontal mounting brackets, ensuring that

the (4) mounting holes on the underside of the

appliance are lined up with the mounting holes

Advertising