Attaching the accessories, Start up, Electrical connection – Karcher HD 10-15-4 Cage Food User Manual

Page 13: Water connection, Connection to the water supply

Advertising
background image

– 3

Mount the nozzle onto the spray pipe.
Tighten covering nut firmly.

Connect ray tube to hand spray gun

Fasten the high pressure hose to the
high pressure connection.

Warning

The appliance may only be connected
to an electrical supply which has been
installed in accordance with IEC 60364.

The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.

The minimum fuse rating required at the
socket outlet is (see technical specifica-
tions).

The appliance should always be con-
nected to the electrical mains using a
plug. It is forbidden to permanently con-
nect the appliance to the power supply.
The plug is only for mains separation.

Check the power cord with mains plug
for damage before every use. If the
power cord is damaged, please arrange
immediately for the exchange by an au-
thorized customer service or a skilled
electrician.

The plug and coupling of the extension
cable used must be watertight.

Use the extension cord that has an ad-
equate cross-section (see "Technical
Data") and unwind it fully from the cable
drum.

Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:

For connection values, see type plate/tech-
nical data.

Warning

Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications

Connect the supply hose (minimum
length 7.5 m, minimum diameter 1“) to
the water connection point of the appli-
ance (such as the tap).

Note
The supply hose is not included.

Open the water supply.

Deaerate the appliance:
Unscrew the nozzle.
Switch on the appliance and let it run
until the water exiting is bubble-free.
At the end let the appliance run for ap-
prox. 10 seconds - then switch off. Re-
peat the procedure for a couple of
times.

Switch off the appliance and fit the noz-
zle again.

Attaching the Accessories

Start up

Electrical connection

Water connection

Connection to the water supply

13

EN

Advertising
This manual is related to the following products: