Safety instructions, Symbols on the machine, Proper use – Karcher HD 10-15-4 Cage Food User Manual

Page 12: Safety devices, Overflow valve with pressure switch, Safety valve, Water shortage safeguard, Before startup, Unpacking, Check oil level

Advertising
background image

– 2

Please follow the national rules and
regulations for fuel spray jets of the re-
spective country.

Please follow the national rules and
regulations for accident prevention of
the respective country. Fuel spray jets
must be tested regularly and the results
of these tests must be documented in
writing.

High-pressure jets can be dan-
gerous if improperly used. The
jet may not be directed at per-
sons, animals, live electrical

equipment or at the appliance itself.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!

Use this appliance exclusively for cleaning
using high pressure jet with/without detergent
(e.g. food industry, disassembly plants...).

While reducing the water supply/quantity
regulation at the pump head, the overflow
valve opens and part of the water flows
back to the pump suck side.
If the lever on the trigger gun is released
the pressure switch turns off the pump, the
high pressure jet is stopped. If the lever is
pulled the pump is turned on again.

The safety valve opens when the permissi-
ble operating pressure is exceeded; water
flows back to the suction side of the pump.
The overflow valve, pressure switch and
safety valve are set and sealed at the fac-
tory.
Setting only by customer service.

The lack of water fuse in the swimmer reservoir
shuts off the engine when the water supply is in-
sufficient (water pressure too low).
The pump is thus protected from running
dry.

Check the contents of the pack before
unpacking.

In case of transport damage inform ven-
dor immediately

Unscrew the palm grip screw to lock the
appliance cover and open the appliance
cover.

Pull out the bottom cover plate on top
and unhook on the bottom.

Read the oil level display when the de-
vice is not running. The oil level must be
between the two markers on the oil res-
ervoir.

Open the lock on the appliance cover
and swivel the appliance cover up-
wards.

Pull out the bottom cover plate on top
and unhook on the bottom.

Cut off tip of oil container cover

Fasten the bottom cover plate and the
appliance cover.

Safety instructions

Symbols on the machine

Proper use

Safety Devices

Overflow valve with pressure switch

Safety valve

Water shortage safeguard

Before Startup

Unpacking

Check oil level

Activate deaeration of oil container