Technical specifications, Hds 9/16-4 st gas, Hds 9/16-4 st gas lpg – Karcher HDS 12-14-4 ST Gas User Manual

Page 29: Hds 12/14-4 st gas, Hds 12/14-4 st gas lpg, Performance data, Mpa (bar), Max. excess operating pressure (safety valve), L/h (l/min), Water connection

Advertising
background image

-

7

Technical specifications

HDS 9/16-4
ST Gas

HDS 9/16-4
ST Gas LPG

HDS 12/14-4
ST Gas

HDS 12/14-4
ST Gas LPG

1.251-108

1.251-109

1.251-110

1.251-111

Performance data
Operating pressure of water (using standard nozzle)

MPa (bar)

16 (160)

16 (160)

14 (140)

14 (140)

Max. excess operating pressure (safety valve)

MPa (bar)

18,5 (185)

18,5 (185)

18,5 (185)

18,5 (185)

Water flow (can be regulated in a phase-less manner)

l/h (l/min)

500-1000 (8,3-
16,6)

500-1000 (8,3-
16,6)

600-1200 (10-
20)

600-1200 (10-
20)

Suction of detergent (can be regulated in a phaseless
manner)

l/h (l/min)

0-50 (0-0,8)

0-50 (0-0,8)

0-60 (0-1)

0-60 (0-1)

Water connection
Min. feed volume

l/h (l/min)

1100 (18,3)

1100 (18,3)

1300 (21,7)

1300 (21,7)

Feed pressure (min.)

MPa (bar)

0,1 (1)

0,1 (1)

0,1 (1)

0,1 (1)

Max. feed pressure

MPa (bar)

0,6 (6)

0,6 (6)

0,6 (6)

0,6 (6)

Electrical connection
Current type

--

3N~

3N~

3N~

3N~

Frequency

Hz

50

50

50

50

Voltage

V

380-420

380-420

380-420

380-420

Connected load

kW

6,4

6,4

7,5

7,5

Electrical protection (slow)

A

16

16

20

20

Type of protection

--

IPX5

IPX5

IPX5

IPX5

Protective class

--

I

I

I

I

Maximum allowed net impedance

Ohm

(0,381+j
0,238)

(0,381+j
0,238)

--

--

Power supply

mm

2

5 x 2,5

5 x 2,5

5 x 2,5

5 x 2,5

Temperature
Max. feed temperature

°C

30

30

30

30

Max. operating temperature of hot water

°C

98

98

98

98

Max. temperature safety thermostat

°C

110

110

110

110

Temperature increase during maximum water flow

°C

60-65

60-65

60-65

60-65

Gross heating performance

kW

75

75

95

95

Chimney draught

kPa

0,01-0,04

0,01-0,04

0,01-0,04

0,01-0,04

Gas connection values
Natural gas E (G 20)

m

3

/h

7,2

--

9,8

--

Natural gas LL (G 25)

m

3

/h

8,2

--

11,4

--

Rated connection pressure (natural gas)

kPa

1,8-5

--

1,8-5

--

Propane

kg/h

--

5,7

--

7,2

Rated connection pressure (Propane)

kPa

--

5-6

--

5-6

Environment data
Rated utilisation level

%

97

97

97

97

Standard emission factor NO

X

(natural gas G 25)

mg/kWh

< 40

--

< 40

--

Standard emission factor CO (natural gas G 25)

mg/kWh

< 40

--

< 40

--

Values for chimney dimensions
Suitability for excess pressure (min.)

kPa

0,05

0,05

0,05

0,05

Draught requirements

kPa

0

0

0

0

Exhaust flow - full load

kg/h

130

130

166

166

CO

2

(Natural gas)

%

9,5

--

9,5

--

CO

2

(Propane)

%

--

12

--

12

Exhaust temperature max./min.

°C

190/150

190/150

170/130

170/130

Combustion air/ air supply

Max. length: 10 n with two 90° arches (min. diameter 100 mm) From the in-
stallation room or fresh outside air - depending on the local regulations.

Condensate drain-out
Condensate drain-out (max.)

l/h

4 (via siphon
into the drain-
age system)

4 (via siphon
into the drain-
age system)

4 (via siphon
into the drain-
age system)

4 (via siphon
into the drain-
age system)

Connectiing piece

DN

40 (HTR)

40 (HTR)

40 (HTR)

40 (HTR)

Minimum water column, siphon

mm

300

300

300

300

29