12

Fault

Possible cause

Remedy

of whom

Indicator lamp for exhaust
gas thermostat (K) is glowing

The exhaust temperature limiter
has been triggered.

Open the hand-spray gun until the plant has
cooled down. Switch the plant off and then on
on the operating panel to unlock the temper-
ature limiter. If the event recurs, call Custom-
er Service.

Operator

Indicator lamp for protection
against calcification (H)
glows

The softener is over.

Refill the softener.

Operator

Inadequate or no flow of de-
tergent

Dosing valve to position "0".

Adjusting the detergent metering valve.

Operator

Detergent filter blocked or tank is
empty.

Clean and/or refill.

Operator

Detergent suction hoses, deter-
gent metering valve or detergent
solenoid valve are leaky or
blocked.

Check, clean.

Operator

Electronics or solenoid valve is de-
fective.

Replace

Customer Service

Full pressure does not build
up in the appliance

Flushed the nozzle.

Replace the nozzle.

Operator

Detergent tank is empty.

Refill detergent.

Operator

Not enough water

Ensure adequate water supply.

Operator

Sieve at the water inlet is blocked. Check, dismantle sieve and clean it.

Operator

Leaky detergent dosing valve.

Check and seal it.

Operator

Leaky detergent hoses.

Replace

Operator

Swimmer valve is jammed.

Check and ensure that it moves freely.

Operator

Safety valve is leaky.

Check the setting; install new washers, if re-
quired.

Customer Service

Flow valve is leaky or has been set
at a low value.

Check valve parts; replace damaged parts;
clean the dirt.

Customer Service

Solenoid valve for pressure re-
lease is defective.

Replace solenoid valve.

Customer Service

High pressure pump is
knocking; manometer is
swaying wildly

Vibration dampener is defective.

Replace vibration dampener.

Customer Service

Water pump does not suck in ade-
quate air.

Check suction system and remove leaks.

Operator

Device continuously turns on
and off while hand spray gun
is open

Nozzle in spray pipe is blocked.

Check, clean.

Operator

Appliance is decalcified.

See section "Descaling".

Operator

Switching point of the over-current
monitor has got shifted.

Get somebody to reset the over-current monitor. Customer Service

Sieve blocked in the water short-
age safe guard.

Check, dismantle sieve and clean it.

Operator

Appliance does not switch off
when the hand-spray gun is
closed

The pump has not been fully vent-
ed.

Set the machine switch to "0" and pull the
hand-spray gun until no fluid comes out of the
nozzle. Turn on the appliance again. Repeat
this procedure until the full operating pres-
sure is reached.

Operator

Safety valve or safety valve wash-
er is defective.

Replace the safety valve and/or the washer. Customer Service

Pressure switch of the overflow
controller.

Check pressure switch and overflow controller.

Customer Service

34