Rack-mount panel (axm-cp/pb), Wiring the touch panel, Preparing captive wires – AMX 8.5" Color Passive LCD Touch Panels User Manual

Page 12

Advertising
background image

Installation

8

Color Passive-Matrix LCD Touch Panels

Rack-mount panel (AXM-CP/PB)

1.

Thread the incoming AXlink and optional RS-232 wiring through the opening in the

equipment rack.

2.

Disconnect the AXlink connector from the Central Controller and disconnect the optional RS-

232 connector from the external RS-232 device connected to the touch panel.

3.

Insert the touch panel into the equipment rack. Line up the top-left and bottom-right screw

holes and start tightening the #6-32 screws. Then, tighten the bottom-left and top-right screws.

4.

Connect the AXlink and RS-232 wiring (optional) to the touch panel. Refer to (DB-9) RS-232

Connector Pinouts table on page 10 for pinout descriptions. The touch panel beeps on

power-up.

Wiring the Touch Panel

The RS-232, AXlink, and PWR (power supply) connectors are located at the rear of the AXT-CP as

shown FIG. 6. The connectors are located on the top-left corner of the rack-mount touch panels as

shown in FIG. 7.

Preparing captive wires

You will need a wire stripper, soldering iron, and flat-blade screwdriver to prepare and connect the

captive wires.

1.

Strip 0.25 inch of wire insulation off all wires and apply a light coat of solder to the ends using

a soldering iron.

2.

Insert each wire into the appropriate opening on the connector according to the wiring

diagrams and connector types described in this subsection.

3.

Turn the flat-blade screws clockwise to secure the wire in the connector. Do not over-torque

the screws; doing so can bend the seating pin and damage the connector.

FIG. 6 AXT-CP (rear view)

FIG. 7 AXD-CP (/PB) and AXM-CP (/PB) (top view)

DB-9 connector

Four-pin AXlink connector

Two-pin power connector

Four-pin AXlink connector

Two-pin power
connector

Do not connect power to the touch panel until the wiring is complete. If you are using
a 12 VDC power supply, apply power to the touch panel only after installation is
complete.

Advertising