35

2. Electrical Service Specifications

IMPORTANT: THE DRYER MUST BE CONNECTED TO THE ELECTRIC SUPPLY

SHOWN ON THE DATA LABEL THAT IS AFFIXED TO THE REAR OF

THE RIGHT HAND ELECTRICAL ENCLOSURE.

WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to the dryer

components due to improper voltage connections will automatically VOID THE

WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

M LG-410 (Gas)

M LS-410 (Steam)

25 HP (ADC Part No. 181006) Blower Motor

7-1/2 HP (ADC Part No. 181017) Drive

E

LECTRICAL

S

ERVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT: 208 VAC

AND

230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE:

A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct

breaker size according to appliance amp draw rating and type of breaker used.

C. Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

MINIMUM

WIRE SIZE

FUSING

Dual Element

Time Delay

CIRCUIT

BREAKER

208

3/4

81

#3

100

110

230

3

78

#3

100

110

380

3/4

49

#6

60

90

416

3/4

44

#6

60

90

460/480

3/4

40

#8

60

80

Advertising