49

NOTE: Lint drawer must be ALL the way in place to activate the safety switch otherwise the

dryer will not start.

9. Rotate the tumbler (basket/drum) by hand to be sure it moves freely.

10. Check bolts, nuts, screws, terminals, and fittings for security.

11. Check to insure air supply (80 PSI [5.512 bars]) is connected to the dryer.

12. STEAM MODELS -- check to insure ALL steam shut-off valves are open.

K. SHUT DOWN INSTRUCTIONS

If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the heat supply:

a. GAS MODELS ... discontinue the gas supply...

1) SHUT OFF external gas supply shut-off valve.

2) SHUT OFF internal gas supply shut-off valves located in the gas valve burner area.

b. STEAM MODELS ... discontinue the steam supply...

1) SHUT OFF external (location furnished) shut-off valve.

2) SHUT OFF internal steam valves located in the supply lines and the return lines.