61203019L1-1

NT1 ACE User Manual

5

NT1 ACE User Manual

The switch labeled TERMINATION sets the Local Bus ter-

mination. The options available are NONE, 50, and 100. See

Powering TEs from the NT1 ACE on page 6 for more informa-

tion concerning Local Bus configurations.

The switch labeled CONFIGURATION has two possible

options. When set in the LONG position, the Local Bus is

configured for Extended Passive Bus. When set in the

SHORT

position, the Local Bus is configured for Short Pas-

sive Bus. Configuration and switch settings are discussed in
Short Passive Bus Configuration

on page 9 and in Extended

Passive Bus Configuration

on page 10.

The Power Supply provides up to 10 watts of power for the

NT1 ACE and the TE. Table 2 gives pin assignments.

Table 2. Network Connector Pin Assignments

Pin

Description

1

No connection

2

No connection

3

No connection

4

U-interface network connection

5

U-interface network connection

6

No connection

7

Negative power input

8

Positive power input

Advertising
This manual is related to the following products: