Extended Passive Bus Configuration

This configuration allows you to connect up to eight TEs at

greater ranges than the Short Passive Bus. This group of TEs

can be located at up to 3000 feet from the NT1, as shown in

Figure 6. To select the Extended Passive Bus configuration,

the CONFIGURATION switch must be set to the LONG

position. A termination resistor must be centrally located to

the TEs. If the TEs have internal terminating resistors that

can be optioned, only one TE’s terminating resistor should

be enabled. The TERMINATION switch should be placed

in the 100 position, and only one of the TEs connected

should be terminated with 100 ohm. These switch settings

should always be maintained, unless an external 100 ohm

resistor is being used. If an external termination resistor is

installed, set the TERMINATION switch to the NONE posi-

tion.

Figure 6. Extended Passive Bus Configuration

TR

TR

NT1

TE

TE

3,000 Feet

*

*

Not needed if NT1's

Termination Resistors
(TR ) are used.

160 Feet