Chapter 2: Hardware setup

2-28

SATA backplane jumper settings and HDD ID assignments

The 6-pin jumper J1 allows you to define your desired SATA configuration.
The picture below shows the location of jumper J1 with pins 1-3 and 2-4
shorted.

Refer to the table for the jumper
settings and the appropriate ID# for
each SATA HDD bay.

J1 setting

(1-3 shorted, 2-4 shorted)

Device

SATA BP ID

Drive Bay 1

CON2

Drive Bay 2

CON4

Drive Bay 3

CON6

Drive Bay 4

CON8

Put a jumper cap over pins 3-5 and 4-6 of the J1 jumper on the
second SATA backplane, if you installed one.

Due to limited power supply, it is not recommended that you install
more than six hard disk drives on this system. If you wish to install
more than six hard disk drives, install a new power supply unit with
a higher power rating.