DN1726-0811

14

VITAL LED Heartbeat Patterns

Communication status and other vital controller parameters can be obtained from VITAL LED heartbeat patterns. It is
located near the RS-232 port (COM3), see Figure 1. This information is particularly useful when connecting the
controller to the rest of the EntraPass system. The following table lists all conditions along with a brief description. Refer
to Table 3, if you must reset or change the communication mode of the KT-400 Ethernet Four-Door Controller.

Table 1: VITAL LED Heartbeat Patterns

Booting Up

Steady

Factory Default DHCP

Continuous LONG Pulses

Unable to Resolve DNS

2 LONG Pulses

Forced Default Static

3 LONG Pulses

DHCP Server Failed

4 LONG Pulses

Receive Broadcast

Single 2.5 Sec. Burst

Card Read or Swipe

Single 0.5 sec burst, resume

previous flash

Hard Reset

4 SHORT Pulses

Corporate Gateway

3 SHORT Pulses

Global Gateway

1 SHORT Pulse

Fail Soft

Continuous SHORT Pulses

Firmware Update

5 pulses / sec @ 50% duty cycle

Rebooting

10 pulses / sec @ 50% duty cycle