Technical specifications – Kantech KT-400 User Manual

Page 19

Advertising
background image

DN1726-0811

15

KT-400 Ethernet Four-Door Controller Installation Manual

Technical Specifications

Type

Description

Power input (KT-400)

Transformer class 2, IN 120 VAC; OUT 16 VAC, 75 VA

Battery back-up (KT-BATT-12)

12 VDC, 7 Ah battery supervised, provides up to 12 hours of operation

Operating Temperatures

From 2°C to 49°C (35°F to 120°F) indoor use only

Humidity Level

0 to 85% (relative humidity non-condensing).

Cabinet Dimensions

(High-Wide-Deep)

37.59 cm (14.8 in) x 30.48 cm (12.0 in) x 12.57 cm (4.95 in)

Cabinet Weight (KT-400)

4.0 kg (8.82 lb)

PCB dimension

22.86 cm (9 in) X 13.97 cm (5.5 in) X 5.20 cm (2.04 in)

Reader types

Wiegand, proximity, ABA Clock and Data, bar code, magnetic, integrated keypad,
smartcard and others

Reader power output

12 VDC and 5 VDC @ 175 mA max each, protected and supervised

Monitored points (inputs)

16 monitored points, single EOL (End of Line), double EOL, without EOL and

1 fixed-function tamper switch input

Points maximum wiring

AWG #22 - 600 m (2,000 ft)

Door strike power

12 VDC, 250 mA max for KT-400 supervised

Reader outputs

16 outputs, 25mA max each, open collector outputs

Auxiliary outputs

LEDs (LED, OUT1 and OUT2) and buzzer (Buz) for each individual door, 25mA max each,

open collector outputs

Relay controlled output

4 onboard Form C Relay controlled outputs, 30 VDC, 3 Amps max each

Communication ports

1 x RS-232 with RJ-12, 1 x RS-485, 1 x Ethernet 10/100Base-T with RJ-45

Expansion port

1 x SPI 6-pin connector, bidirectional data exchange supported. Supplies 12 VDC, 500 mA
max shared with 12 VDC Auxiliary port

Auxiliary port

1 x Auxiliary 12 VDC, 500 mA maximum shared with SPI expansion port

Communication speed

- Up to 115200 Bauds (automatic detection) over RS-232 and RS-485
- 10/100 Mb/s BaseT over Ethernet

Flash memory

16 MB for application storage

RAM memory

64 MB for application loading and running, protected by a Lithium-Ion battery for a
minimum of 75 hours

Network autonomy

Distributed data and processing

Certifications / Listing

EN55022, EN61000-6-1, EN61000-6-2
FCC: Class A
UL 294, UL 1076