67

To and CC:

Enter the recipient email address and separate it with comma or a semicolon
(;).

Subject:

Enter the message title.

Message:

Type the message.

(3) Email Notice Setting

Notice Interval:

Set the period of time before it sends another e-mail notice.

Embedded image

: Select the image size and set the number of frames.

Attach image when sensor is triggered:

When the sensor is triggered, the system will

capture the image and send the image to the certain e-mail address with the alarm
message.

(4) Modem Dial up Setting

If you are using dial up modem, enable Auto Dial up check box and select the modem
name. You may also set the time to disconnect automatically, just enable the Auto
Disconnect after

check box and set time.

5.9.5 To Setup FTP Setting:

1. Beside the File Transmission via FTP check box,

click Detail.

2. In the FTP Setting dialog box, enter the FTP IP, port,

user ID and password.

3. In

Number of Pic

text box, enter the number of

sequence images that want to send when file is
transmitting. The maximum number of picture can be
transmitted are 16.

4. In

Upload image when sensor is triggered

, select the camera that the images will be

capture and send when the sensor is triggered.

5. Click

OK

to exit and save the setting and Cancel to exit without saving the setting.

5.9.6 To Setup Alarm Recording Setting:

1. Beside the Start Recording check box, click

Detail

.

2. In the Alarm Recording Setting dialog box,

select the camera to enable/disable video
recording. Enable All to select all cameras.

3. In the Frame Rate selection, select As Setting

to record the number of frames based on the
Recording Setting or Max to record the
maximum of frames based on the available
speed.

4. In

the

Stop Recording after

text box, mark and set the number in second for the

program to continue recording after the alarm has ended. The time range is 1~600
seconds. If user doesn’t mark and set the time, the alarm recording will continue
recording until alarm is reset.

5. Click

OK

to accept the new settings and Cancel to exit without saving.