17

Chapter 3: Operations

Overview

The CPS and its ports can be easily configured and managed to meet your

requirements for device connection, user authentication, access control, power

status monitoring, port history information display and SNMP compliance for

use with third-party network management products. Support for SSH (Secure

Shell) access via third-party clients is also provided.

Configuring Serial Port Settings

You can configure a CPS port to support one of two types of target devices

(TDs): SPC and console.

The SPC power distribution TD provides enhanced security options, including

password protection, port-specific access rights and port groupings. For more

information, see the SPC Installer/User Guide.

A console TD can be a router, firewall, server or other supported serial device.

By default, CPS ports are configured with the following settings.

Target device

Console

Name

xx-xx-xx Pn (last 3 octets of MAC address

plus the port number)

Baud rate

9600

Bits per character

8

Parity

None

Stop bits

1

Flow control

None

Time-out 15

minutes

CLI access character

Use Server CLI setting (^D)

Power

None

Most of these settings are standard serial port operating characteristics.

The CLI access character parameter specifies how you access the CLI. For

more information, see CLI mode in this chapter.

The Power parameter instructs the CPS to monitor the state of a specified

control signal. The parameter value indicates an inbound control signal

(CTS, DCD or DSR) and the state of that signal (low or high). When the

defined signal is true, the CPS interprets it as a power on condition for the

attached device; when the signal is false, a power off condition for the device

is assumed. The signal specified for flow control cannot be used for power

control, and vice versa.