Pressing the KNEE button brings up this page:

Compressor Knee: 40

(0 is hard)

The Knee control adjusts the sharpness of the transitions

between uncompressed and compressed signals. As

a signal increases in level through the threshold, the

compressor will begin to apply gain reduction. With a

soft knee (100), that change in gain will be gradual and

therefore less noticeable.
The range of the control is from 0 (hard knee) to 100 (soft

knee). (The default setting is 48.)

Gate Page

ª

Pressing the GATE button brings up this page:

Th:-36dB_____|
Gate Ratio: 1:20

This page allows you to set the main Gate parameters.

Use the cursor buttons to move from field to field and the

Data Knob to set each parameter. For ease in setting the

threshold, this page includes a display of the incoming

signal level and a graphic indication of the currently

selected threshold. The threshold should be set just above

the level of the signal that you wish to gate.
Pressing the GATE button again while the Gate Page is

displayed will display the Gain Reduction Meter Page

(see below). Continually pressing the GATE button will

alternate between the two pages.
The ranges of the parameters are as follows:

Threshold: –90 dB (default setting) - 0 dB
Ratio: 1:1.0 (default setting) - 1:99

Gain Reduction Meter Page

ª

C/G:-20 -12 -6 -3 0

¡¡¡¡¡¡¡¡¡¡¡

Pressing either the COMP or GATE buttons while their

respective pages are displayed will display this high

resolution gain reduction meter. The meter displays the

amount of gain reduction applied to the signal. When the

input signal is above the compression threshold or below

the gate threshold, the gain reduction meter will display

the amount of compression or gating being applied.

Pressing the COMP or GATE button again will return to

the appropriate page.

Gain Reduction Meter

ª

The front panel GAIN REDUCTION meter is intended

to provide a quick indication of compressor and gate

activity. For precise gain reduction indication, refer to the

Gain Reduction Meter Page described above. The range of

the meter is 15 dB.

COMPRESSOR/GATE ON Button

ª

When this button is lit, the COMPRESSOR/GATE module

is active. When it is not lit, the module is bypassed.

Pressing the button toggles its state. The Comp/ Gate On/

Off function can also be controlled by MIDI and/or by a

footswitch.

DE-ESSER MODULE

De-esser Page

ª

Pressing the DE-ESS button brings up this page:

This page allows you to set the main de-esser parameters.

Use the cursor buttons to move from field to field and the

Data Knob to set each parameter. For ease in setting the

threshold, this page includes a display of the incoming

high-pass signal level and a graphic indication of the

currently selected threshold. The threshold must be set

below the signal peaks for any de-essing to occur.
Pressing the DE-ESS button again while the De-esser

Page is displayed will display the De-esser Gain Reduction

Meter Page (see below). Continually pressing the DE-ESS

button will alternate between the two pages.
The ranges of the parameters are as follows:

Threshold: –60 dB - 0 dB (default setting)
Ratio: 1.0:1 - 99:1

NOTE

If you are using the Double Track function (see below), the

de-esser works on both the main and the double track.

De-esser Attack Page

ª

Pressing the ATK button brings up this page:

De-esser Attack

15 ms

The Attack Time control adjusts the speed with which the

de-esser’s compressor element responds to peaks in the

signal coming from the highpass filter. The range of the

control is from 0 milliseconds to 200 milliseconds. (The

default setting is 15 milliseconds.)

De-esser Release Page

ª

Pressing the REL button brings up this page:

5 – Operation