Problem:

Possible Cause:

Solution:

Burner will not light
using the ignitor

Burner is not connected to
Valve.

Not pausing long enough
before clicking the Ignitor

No spark

LP gas cylinder is empty

LP Coupling nut is not fully
connected to regulator

LP Excess flow valve tripped
in regulator

Obstructions in burner

Electrode and burner are wet

Wire is loose or disconnected

Wire is shorting (sparking
between ignitor wire and
electrode)

Make sure burner tube is over the gas nozzle. See How to Clean
the Burners #6 page 20: Re-install after cleaning.

When lighting the Burner, push-in and turn control panel knob
counter-clockwise to the high position. Pause 4 seconds, then
Push in Ignitor button several times so that it clicks each time.

Gas collector tab is bent (making too large or small of a gap
between electrode and tab). By hand, bend gas collector tab back
within a maximum of 3/16” gap to electrode. (See page 14 for
illustration).

Take LP gas cylinder to licensed LP gas supplier to be refilled

Tighten coupling nut by hand about one-half to three quarters
additional turn. Do not use tools.

Turn control knobs to “off” position and turn LP gas cylinder handle
clockwise until it stops. Wait five minutes. Relight LP gas grill. If
flame remains to be low, turn off gas at cylinder and grill.
Disconnect the regulator from the LP gas cylinder. Reconnect the
regulator to the LP gas cylinder. Perform a leak test. Relight grill.
This will reset the excess flow valve.

See How to Clean the Burners page 20- Re-install after cleaning

Dry electrode with clean cloth. Air dry or use blow dryer.

Reconnect the wire

Replace ignitor wire/electrode assembly (Call the Customer Service
Department)

Make sure gas Collector and Ignitor are tight.

TROUBLESHOOTING

20

LP gas cylinder is empty

LP Excess flow valve tripped
in regulator

LP Coupling nut is not fully
connected to regulator

Obstructions in burner

Take LP gas cylinder to licensed LP gas supplier to be refilled.

Turn control knobs to “off” position and turn LP gas cylinder handle
clockwise until it stops. Wait five minutes. Relight LP gas grill.

Tighten coupling nut by hand about one-half to three quarters
additional turn. Do not use tools.

See How to Clean the Burner page 20- Re-install after cleaning

Burner will not light
using a match

Burner is not connected to
Valve.

Make sure burner tube is over the gas nozzle. See How to Clean
the Burners page 20- Re-install after cleaning.

Gas in LP Cylinder is low

Excess flow valve tripped in
regulator

Check LP gas cylinder. Refill if necessary.

Turn control knobs to “off” position and turn LP gas cylinder handle
clockwise until it stops. Wait five minutes. Relight LP gas grill. If
flame continues to be low, turn off gas at cylinder and grill.
Disconnect the regulator from the LP gas cylinder. Reconnect the
regulator to the LP gas cylinder. Perform a leak test. Relight grill.
This will reset the excess flow valve.

Low flame
or low heat

Natural Gas supply pressure
is low

Check shut-off valve. Check for leaks supply line pressure.

OR