Stove Installation

(for qualified installers only)

Travis Industries

100-01140

4 020628

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered
an alcove installation. Because of the reduced height, the special installation requirements listed
below must be met.

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

Rainier-45°

Rainier-90°

Minimum Clearance
(See the illustration below)

Combustible

Alcove

Non-Combustible

Alcove

Combustible

Alcove

Non-Combustible

Alcove

A

Sidewall to stove

16"

6"

14"

6"

B

Backwall to stove

14"

4"

9 1/2"

2"

D

Connector to sidewall

25 1/2"

15 1/2"

23 1/2"

15 1/2"

E

Connector to backwall

10"

2"

10 1/4"

2 3/4"

G

Maximum depth of alcove

48"

48"

48"

48"

H

Minimum width of alcove

57 3/4"

37 3/4"

53 3/4"

37 3/4"

J

Minimum height of alcove

84"

6" above stove top

84"

6" above stove top

Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have
walls and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete).
This non-combustible material must be spaced and ventilated at least 1" off of all combustible
materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling.
All other alcoves are considered combustible. The clearances below must be met:

Non-combustible alcove
construction (on walls
and ceiling) - see the
explanation above.

3 1/2" thick non-
combustible
material

Combustible

materials

1" Min.

Ventilated
air space

Non-combustible
reinforcer

a

b

d

e

h

j

g