Listing label, Model – Avalon Stoves Rainier User Manual

Page 36

Advertising
background image

36

Listing Label

Travis Industries

100-01140

4 020628

MODEL:

Rainier 90

Rainier 45

990 (Top Flue)

945 (45°

Flue)

10850 1

17th Pl. N.E. Kirkland, W

A

98033

Manufactured By:

Combustible floor beyond hearth must be protected by a minimum 0.25 inches thick insulating board, having a thermal conductivi

ty of

K

=

0

.72 BTUs in/Ft÷

-hr °

f

at

800°

f, or equivalent. (See Owners Manual for examples)

All fireplace installations require facing shroud plates. Do not remove firebrick or mortar from masonry fireplace. Install wit

h or without a direct flue connection.

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with July 1990 particulate emission standards.

Date of Manufacture

2002 2003 2004 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.

DO NOT REMOVE THIS LABEL Made in U.S.A.

0338 (IGN)

Serial Number

Tested to: UL 1482 AND APPLICABLE SECTIONS OF UL 127, 737 AND 907.

FOR USE WITH SOLID WOOD FUEL ONLY

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT

INSTALLATION AND RESTRICTIONS IN YOUR AREA.

ROOM HEATER SOLID FUEL TYPE APPLIANCE ALSO FOR USE IN MOBILE HOMES

SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES.

DO NOT REMOVE THIS LABEL

Report #028-S-45-4

PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer

’s installation and operating instructions. Contact your local building

or fire officials about restrictions and installation inspection in your area. Refer to local building codes and manufacturer

’s instructions for precautions

required for passing a chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall

or ceiling. Do not

connect this unit to a chimney flue serving another appliance. Clearances may be reduced by methods specified in NFPA

211, liste

d wall shields, pipe

shields, or other means approved by local building or fire officials. Inspect and clean chimney frequently, under certain condi

tions of use creosote build

up may occur rapidly. Do not overfire. If heater glows, you are overfiring. Maintain 36

front clearances to all furnishings and other combustible

materials. Do not use grate or elevate fire, build wood fire directly on hearth. Operate only with door closed.

OPTIONAL EQUIPMENT: Front or rear blower (electrical rating: 115V, 60 Hz., 1.8 Amps)

Replace glass only with AVALON supplied NEOCERAM ceramic glass (5mm).

Do not route power cord under or in front of appliance.

DURAVENT model DVL with DURA-PLUS chimney

AMERI-TEC model DCC with model HS

chimney

SECURITY model DP with SECURITY

model ASHT

or S2100 chimney

GSW model Super Chimney Twenty-One connected directly to appliance

SELKIRK METALBESTOS model DS connector with model SSII chimney

DURAVENT Model DVL with DURA-TECH chimney

FREESTANDING INSTALLATION

STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6

diameter, minimum 24 MSG black or 25 MSG blued steel connector,

with listed UL-103 HT factory-built chimney, suitable for use with solid fuels or masonry chimney. Pedestal or legs are require

d.

ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required. Maximum alco

ve

depth 48

, minimum alcove height 84

.

MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition,

mobile home installations require outside air - use the Avalon Rainier optional pedestal or outside air boot.

Pedestal or legs are required.

COMBUSTIBLE FACING

MANTEL

HEARTH

EXTENSION

INSERT

COMBUSTIBLE SIDEWALL

NON-COMBUSTIBLE

FIREPLACE F

ACING

AB

C

D

F

E

LISTED FIREPLACE INSERT FOR INSTALLATION INTO A FACTORY-

BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE

Minimum Clearance to

Masonry

Factory-Built

Combustibles and Hearth

Fireplace

(Z.C.) Fireplace

Requirements

Installations

Installations

A.

14.0”

30.0”

B.

13.0”

12.0”

C.

29.5”

12.0”

With Shield

14.5”

N/A

D.

31.5”

24.0”

With Shield

16.5”

N/A

Hearth Extension Front

16”

16”

Hearth Extension to Sides

8”

8”

Rainier 90

Singlewall connector

Conventional residential

Installation

Rainier 45

Singlewall connector

Conventional residential

Installation

Rainier 45

Alcove, Mobile home, and reduced clearance conventional residential

Installation

Rainier 90

Alcove, Mobile home, and reduced clearance conventional residential

Installation

A.

B.

C.

D.

E.

F.

Sidewall to Unit

Backwall to Unit

Corner to Unit

Sidewall to Connector

Backwall to Connector

Corner to Connector

14.0 in.

14.5 in.

11.0 in.

24.0 in.

15.75 in.

20.0 in.

14.0 in.

0

9.5 in.

0

7.5 in.

23.5 in.

10.25 in.

16.0 in.

14.0 in.

17.5 in.

11.0 in.

24.0 in

15.5 in.

16.5 in.

16.0 in.

14.0 in.

0

7.5 in.

25.5 in.

10.0 in.

12.0 in.

Minimum Clearance to Combustible Materials - Freestanding Installation

Freestanding Clearance Diagram

Floor Protection Diagram

Alcove Specifications

Max.

Alcove Depth 48 in.

Min.

Alcove Height 84 in.

Min. Alcove

W

idth

990: 53.5 in.

945: 57.5 in.

Floor protection must be a non-com-

bustible material extending beneath the

heater and to the front, sides and back

as indicated. See Owner's Manual for

examples of non-combustible materials

that can be used.

FRONT

ST

OVE

FLOOR PROTECT

OR

6

6

6

16

45

˚

ST

OVE

ST

OVE

ADJACENT W

ALL

ADJACENT WALL

BACKW

ALL

SIDEWALL

E

D

F

B

A

C

Factory-Built (Z.C.) Fireplace installations require a minimum 24

starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.)

Fireplace chimney must have a minimum cross-sectional area of 28.85

. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or secured in the

open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer

’s installation instructions. Factory-Built (Z.C.) Fireplace floor protection

must be 3/8

minimum non-combustible material or equivalent, extending 16

in front of insert and 8

to both sides. A metal deflector plate must be installed if the

flue collar is not completely behind the lintel plate of the Factory-Built (Z.C.) Fireplace openings.