Stove Installation

(for qualified installers only)

Travis Industries

100-01140

4 020628

S t a n d a r d
Ceiling with
a Factory
B u i l t
C h i m n e y

Chimney Cap

(See the section "Chimney

Termination Requirements"

for more details)

Chimney Sections

Minimum Air Space to

Combustibles (See

Chimney Manufacturer's

Instructions - usually 2")

Chimney Connector Sections

Follow the chimney

manufacturer's instructions

and clearances for roof

penetrations. A storm collar

and flashing are required

(some require a radiation

shield).

}

}

Minimum 15'

Maximum 33'

Stove Clearances

(See the section "Stove

Placement Requirements"

for more details)

Floor Protection

(See the section "Floor

Protection Requirements"

for more details)

Follow the chimney

manufacturer's instructions

and clearances for floor

penetrations. A ceiling

support is required, an attic

insulation shield is required

where insulation is present.

Insulation

C a t h e d r a l
Ceiling with
a Factory
B u i l t
C h i m n e y

Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)

Chimney Sections

Minimum Air Space to
Combustibles (See Chimney
Manufacturer's Instructions -
usually 2")

Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required
(some require a radiation
shield).

}

Minimum 15'
Maximum 33'

Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)

Floor Protection
(See the section "Floor
Protection Requirements"
for more details)

Chimney
Connector
Sections