Stove installation, Mobile home requirements – Avalon Stoves Rainier User Manual

Page 13

Advertising
background image

Stove Installation

(for qualified installers only)

13

Travis Industries

100-01140

4 020628

Mobile Home Requirements

Outside air must be installed - see "Outside Air Requirements" on page 11

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance

adapter for the connector being used.

Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)

Minimum Clearance
(See the illustration below)

Rainier-45°

(With Reduced

Clearance Connector)

Rainier-90°

(With Reduced

Clearance Connector)

A

Sidewall to stove

16"

14"

B

Backwall to stove

14"

9 1/2"

C

Cornerwall to stove

7 1/2"

7 1/2"

D

Connector to sidewall

25 1/2"

23 1/2"

E

Connector to backwall

10"*

10 1/4"

F

Connector to cornerwall

12"*

16"

*

These are minimum clearances, not installation dimensions. Connector position will vary
depending upon brand. First establish the stove clearances, install the 45° connector to the stove, then
determine the position of the connector.

Straight Installations

a

b

d

e

Corner Installations

c

f

NOTE:
Measure clearances to the stove top.

If using offsets, use the connector clearance listed to the
right, not the connector manufacturer's
c l e a r a n c e
.

The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor
and stove to insure the stove does not dislocate.

Mobile home installations require a spark arrester at the
chimney termination.

The appliance must be grounded to the chassis of the
mobile home (consult your building official).

WARNING:

DO NOT INSTALL IN SLEEPING ROOM.

CAUTION:

THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.

Minimum Stove
Clearance
(as outlined above)

12-1/4”
Min.

Minimum Connector
Clearance
(as outlined above)

Advertising