Plumbing – Airstream INTERNATIONAL CCD User Manual

Page 63

Advertising
background image

F

F - 2

PLUMBING

AUTOMATIC GAS REGULATOR

All models are equipped with an automatic

gas regulator. Both tanks are connected to

this regulator.

When the gas is turned on it is drawn from

only one tank at a time. When the tank being

used is depleted the regulator automatically

switches to the full tank. An indicator in the

regulator knob points toward the tank that

was being used to give you a visual reminder

when one tank is empty.

Operation

Make sure there is propane in both cylinders before you start. Rotate the black lever

on the top front side of the regulator toward the cylinder you want to use first. This will

be the “service” cylinder and the other will be the “reserve” cylinder. Slowly open both

tank valves completely, then close about 1/4 turn. This will allow you to easily check

to see if valves are open or closed. The indicator on the top of the regulator will turn

bright green. The indicator color will stay green as long as there is fuel coming from

the service side. When the service cylinder empties, the regulator will start drawing

from the reserve cylinder providing an uninterrupted fuel flow to the system. When it

switches over, the indicator color changes from green to red. This red color indicates

that the service cylinder is empty and needs to be filled.

Now disconnect the cylinder and have it refilled. After filling, reconnect the pig- tail and

slowly open the cylinder valve. The full cylinder now becomes the reserve.

LPG BOTTLES

The following step-by-step procedure gives you the proper method of removing and

installing these bottles:

1. Rotate the black lever all the way over towards the reserve cylinder. The indicator

will turn green and the reserve cylinder becomes the service cylinder. Now shut off

the cylinder valve on the empty cylinder.

2. Disconnect the green swivel nut from the cylinder valve at the bottle to be removed.

(This fitting has a common right hand thread and turns in the same direction to most

threaded fittings.)

3. Turn the large clamping “T”’ handle counterclockwise until the hold down bracket

is loose enough to remove the bottle. If your trailer is equipped with a gas bottle

cover the “T”’ handle must be removed, and then remove the cover before remov-

ing the bottle.

DO NOT REMOVE THE CENTER HOLD DOWN ROD!

To Install

1. Place the bottle in position on the “A” frame and bottle cross member so that it

rests on the upper collar of both bottles with the collar rims engaged in the grooves

on the underside of the bracket. If your trailer is equipped with a gas bottle cover it

should be positioned over the bottles next. Make sure the hold down rod projects

up through the hole in the shroud center bracket.

2. Replace the “T” handle and tighten down until the bottles are held firmly in place.

3. Hand-tighten the green nylon swivel nut onto the tank valve outlet.

4. Turn on gas shut off valves and test all fittings with a soap suds or detergent solution

and watch for bubbles.

Change-Over
Lever

Inlet

High-Pressure
Regulator

Indicator
Window

Inlet

Second-Stage
Regulator

Outlet

Vent

Advertising