Pinouts, signals, and functions, Nxc-irs4 channel assignments, Programming information – AMX NetLinx NXM Series User Manual

Page 26

Advertising
background image

NXC-IRS4 4-Port IR/S Control Card

20

NetLinx Cardframe, Control Cards, and NetModules

Pinouts, Signals, and Functions

NXC-IRS4 Channel Assignments

The NXC-IRS4 channel settings listed in the following table set the IR output channels. The
NXC-IRS4 can process up to two IR or serial device channel setting commands simultaneously.

Programming Information

The following NetLinx Send_Commands control the NXC-IRS4 Control Card.

NXC-IRS4 Pinouts, Signals, and Functions

Pin Signal

Function

Pin Signal

Function

1

GND

Signal ground

10

Input #1

Logic input

2

Output #1

IR data

11

Input #2

Logic input

3

GND

Signal ground

12

Input #3

Logic input

4

Output #2

IR data

13

Input #4

Logic input

5

GND

Signal ground

14

Power

+12 VDC

6

Output #3

IR data

15

----------------- no connection

7

GND

Signal ground

16

----------------- no connection

8

Output #4

IR data

17

----------------- no connection

9

GND

Signal ground

18

----------------- no connection

19

----------------- no connection

20

----------------- no connection

NXC-IRS4 Channel Assignments

Channel

Description

1-255

Generate the IR or serial command assigned to that channel.

1-199

Provide intelligent feedback; if a channel with no IR command turned On, the card will turn that
channel Off.

Ports 1-4

Generate PUSH and RELEASE statements corresponding to the state of inputs 1 - 4.
A contact closure to GND is reported as a PUSH.
• The PUSH and RELEASE channel is 255.
• Channel reporting status is 255.
• Channel 255 changes are disabled after receipt of the ’PON’ command.

NXC-IRS4 Send_Commands

Command

Description

CAROFF
Disable the IR carrier signal
until a 'CARON' command is
received.

Syntax:

SEND_COMMAND <DEV>,"'CAROFF'"

Example:

SEND_COMMAND IR_1,"'CAROFF'"

Stops transmitting IR carrier signals to the IR_1 port.

CARON
Enable the IR carrier signals
(default).

Syntax:

SEND_COMMAND <DEV>,"'CARON'"

Example:

SEND_COMMAND IR_1,"'CARON'"

Starts transmitting IR carrier signals to the IR_1 port.