Nxc-vai4 analog voltage control card, Specifications – AMX NetLinx NXM Series User Manual

Page 35

Advertising
background image

NXC-VAI4 Analog Voltage Control Card

29

NetLinx Cardframe, Control Cards, and NetModules

NXC-VAI4 Analog Voltage Control Card

The NXC-VAI4 Analog Voltage Control Card (FG2025) provides four independent analog-to-digital inputs
and four independent digital-to-analog outputs, which are controllable over the ICSP network. Each port can
be configured for a variety of DC input and output signals. The NXC-VAI4 incorporates the functionality of
the AXC-VAI2 and AXC-VRG AXlink cards. FIG. 7 shows the VAI4 card:

Specifications

FIG. 7

NXC-VAI4 Analog Voltage Control card

NXC-VAI4 Specifications

Power Requirements

330 mA @ 12 VDC

Inputs

Four high-impedance analog DC inputs.

Outputs

Four analog DC outputs (user-configurable).

D/A, A/D conversion

A/D and D/A converters for analog sampling and control. 8 or 10-bit; user-
selectable via the ADMODE Send_Command (see theProgramming
Information
section on page 34
for details)

Available input voltages

0 V to +12 V

Available output voltages:

-12 V to +12 V

The output voltage may be software-configured for any min. and max. levels
between -12 and +12 VDC.
• Maximum output current = 60 mA per output.
• Over-voltage protection to +28 VDC.

External reference

A user supplied external reference voltage can be used to set the maximum
voltage range for the D/A outputs. The full analog output range is scaled to fit
the maximum range set by the external reference.
Output voltage may be set to any level between 0-12 VDC, referenced to the
external reference voltage input and NXC-VAI4 power supply GND.

External reference input:
(EREF - one for each output)

• Maximum external reference input voltage = +12 VDC.
• Over-voltage protection to +28 VDC.

Internal reference output:
(IREF)

• +5 V reference output, maximum current = 60 mA.
• This output is intended to drive a ground-referenced load.

Advertising