Low Silhouette Ducted Type (F1 Type)

3-22. Required Minimum Space for Installation and

Service

This air conditioner is usually installed above the

ceiling so that the indoor unit and ducts are not

visible. Only the air intake and air outlet ports are

visible from below.

The minimum space for installation and service is

shown in Fig. 3-56 and Table 3-4.

It is recommended that space be provided (17-23/32"

×

17-23/32") for checking and servicing the

electrical system.

Fig. 3-57 and Table 3-5 show the detailed

dimensions of the indoor unit.

Table 3-4

Unit: inch (mm)

Type

26

36

A (Length)

42-17/32 (1,080)

61-13/32 (1,560)

Number of duct flanges 3

4

A B C D E F G H

I J K

35-7/16

9-21/32

S-26PF1U6

37-7/8

(7-3/32Ч5)

39-3/8 42-17/32

11-13/32

2-23/32 38-19/32 39-31/32 5-1/8

(9-21/32Ч1)

9-27/32 12 16

54-11/32

19-9/32

S-36PF1U6

56-25/32

(9-1/16Ч6)

58-9/32 61-13/32 13-3/16 12-7/32 57-15/32 58-27/32 5-1/8

(9-21/32Ч2)

9-7/16 16 18

No. of

holes

Dimension

Table 3-5

Unit: inch (mm)

Refrigerant tubing joint (liquid tube)
Refrigerant tubing joint (gas tube)
Upper drain port (O.D. 1-1/4 in.)
Bottom drain port (O.D. 1-1/32 in.)
Suspension lug
Power supply outlet (2-ø1-3/16 hole)
Fresh air intake port (ø5-29/32 hole)
Flange for the flexible air outlet duct (ø7-7/8 hole)
Tube cover
Electrical component box
Flange for the air intake duct
(Option or field supply)

9

10

9

10

11

11

(Suspension bolt pitch)

)

h

c t i

p t

l

o

b

n

o i

s

n

e

p

s

u

S (

M-ø1/8

(Hole)

4-ø15/32

(Hole)

(Hole)

A (O.D.)

L-ø1/4

I

13/32

13/32

2

3 /

3

1

2

3 /

5 -

2

8 /

7 -

7

2

3 /

5 -

2

2

3 /

3

1

I

J

J

K

B

C
D

(5-29/32)

1-9/16

E

E

E

F

2-15/16

2-9/16

11-7/32

2-3/4

5-1/8

31/32

8-9/32

12-7/32

31/32
6-7/8

1-3/8

3-17/32

1-7/32

1-7/32

H (Duct suspension bolt pitch)

G (Ceiling opening dimension)

2

3 /

1

3

6

1 /

5

1 -

3

2

3 /

9 -

7

2

3 /

7

2 -

2

2

2

3 /

1

3

2

3 /

7

1 -

4

2

3 /

5

1 -

7

2

3 /

1

1 -

3

2

3 /

1

3

6

1 /

3 -

1
4 /

3 -

2

6

1 /

5 -

6

2

3 /

1

3

6

1 /

3

1 -

4

2

2

3 /

3

1

2

3 /

5

1 -

3

6

1 /

3

1 -

0

1

)

n

o i

s

n

e

m i

d

g

n i

n

e

p

o

g

n i l i

e

C (

4 /

1 -

0

1

) .

D .

O (

3/4

3/4

Inspection access

(17-23/32

×

17-23/32)

(Field supply)

Inspection access panel

Ceiling

Indoor Unit

Inspection
access

17-23/32

×

17-23/32

Air outlet duct flange

min.
9-27/32

.

ni

m

4/

3-

5

1

min. 25-19/32

2

3/

7

2-

2

2

A (Suspension bolt pitch)

Electrical
component box

Refrigerant
tubing

Unit: inch

.ni

m

23/

72

-9

Fig. 3-56

Fig. 3-57

L M

Unit: inch

Type

Panasonic_PAC-i_IndoorUnit_US-le30 30

Panasonic_PAC-i_IndoorUnit_US-le30 30

2011/11/02 15:17:27

2011/11/02 15:17:27

Advertising
This manual is related to the following products: