Panasonic 36PET1U6 User Manual

Page 38

Advertising
background image

38

Inter-unit

power wiring

Power wiring

Inter-unit

control wiring

8P terminal board

C Type (Outdoor Unit)

U1 U2 1 2 G L1 L2

U2

U1

L1

L2

U1

U2

1

2

G

2

1

WHT

Remote
controller

B

C

Indoor

unit

L1
L2

Grounding line

BLK

2

1

Inter-unit power line

208 / 230 V, 60 Hz

Power supply
208 / 230 V, 60Hz

Grounding line

A

Outdoor unit

INV unit

1

2

G

*

U2

U1

L1

L2

U1

U2

1

2

G

Indoor

unit

L1
L2

Grounding line

Inter-unit power line

208 / 230 V, 60 Hz

Power supply
208 / 230 V, 60Hz

Grounding line

A

Outdoor unit

INV unit

1

2

G

*

* Disconnect switch

Field supply

Indoor Unit

Type

Time delay fuse or

circuit capacity

U1, K1, T1, F1

15 A

Control Wiring

(A) Inter-Unit Control Wiring

(B) Remote Control Wiring

(C) Control Wiring For Group Control

AWG #18

Use high voltage wire (300 V)

*1

AWG #18

*2

(0.75 mm

2

)

AWG #18

*2

-

(0.75 mm

2

)

0

5

6

.

x

a

M

.

t

f

0

5

6

,

1

.

x

a

M

.

t

f

0

0

3

,

3

.

x

a

M

-

ft. (Total)

AWG=American Wire Gauge

*1

With ring-type wire terminal

*2

Wire joint connection

4-3. Wiring System Diagrams

Basic wiring diagram for standard control

NOTE

Disconnect switch may be needed by the National/Local code.

ALWAYS COMPLY WITH NATIONAL AND LOCAL
CODE REQUIREMENTS.

NOTE

(1) Refer to Section 4-2. Recommended Wire Length

and Wire Diameter for Power Supply System for the
explanation of “A”, “B” and “C” in the above diagrams.

(2) Inter-Unit Control Wiring (A) and remote control

wiring (B), (C) have no polarity. But for other wiring,
respect polarity. Be sure to connect as shown in the
Wiring System Diagram.

(3) In case of separate supply connection to indoor unit,

over current protection must be provided between
power source and indoor unit.

MAXIMUM OVER CURRENT PROTECTION 15 A
(FUSE OR HACR TYPE CIRCUIT BREAKER)

Panasonic_PAC-i_OutdoorUnit_US-l22 22

2011/07/08 9:46:23

L1 L2

Unit

control

Line

Unit

control

Line

U1

Power

supply

Power

supply

U2

5P terminal board

U1, T1, F1 Types

Remote

control

Line

Remote

control

Line

5P terminal board

L1 L2

U1 U2

K1 Type

U2

L2

U1

L1

L1

L2

U1

U2

L2

L1

2

1

WHT

Remote
Controller

B

C

Indoor

unit

L1
L2

Grounding line

BLK

2

1

Inter-unit power line

208 / 230 V, 60 Hz, 1-PH

Power supply
208 / 230 V, 60Hz, 1-PH

Grounding line

A

Outdoor unit

INV unit

1

2

G

*

U2

U1

L1

L2

U1

U2

Indoor

unit

L1
L2

Grounding line

Inter-unit power line

208 / 230 V, 60 Hz, 1-PH

Power supply
208 / 230 V, 60Hz, 1-PH

Grounding line

A

Outdoor unit

INV unit

1

2

G

*

* Disconnect switch

Field supply

Wire joint
connection

Wire joint
connection

NOTE

Disconnect switch may be needed by the National/Local code.

ALWAYS COMPLY WITH NATIONAL AND LOCAL
CODE REQUIREMENTS.

NOTE

(1) Refer to Section 4-2. Recommended Wire Length

and Wire Diameter for Power Supply System for the
explanation of “A”, “B” and “C” in the above diagrams.

Panasonic_PAC-i_OutdoorUnit_US-l22 22

2011/07/08 9:46:23

L1 L2

Unit

control

Line

U1

Power

supply

U2

5P terminal board

U1, T1, F1 Types

Remote

control

Line

K1 Type

Panasonic_PAC-i_IndoorUnit_US-le38 38

2011/07/11 21:19:05

Panasonic_PAC-i_IndoorUnit_US-le38 38

Panasonic_PAC-i_IndoorUnit_US-le38 38

2011/11/02 15:17:31

2011/11/02 15:17:31

Advertising
This manual is related to the following products: